Efficiency of an enclosed afferent reservoir breathing system during controlled ventilation.

نویسندگان

  • P M Droppert
  • G Meakin
  • P C Beatty
  • A J Mortimer
  • T E Healy
چکیده

We describe an enclosed afferent reservoir (EAR) breathing system developed by Ohmeda and designed to operate efficiently in spontaneous and controlled ventilation. The efficiency of the system was evaluated by calculating the fractional utilization of fresh gas in 10 ASA I-III patients during anaesthesia with controlled ventilation. Maximum efficiency occurred when the minute ventilation to fresh gas flow ratio was greater than 1.5. Under these conditions, fractional utilization was relatively constant with a value of 0.73 (95% confidence interval 0.69-0.78). The minimum fresh gas flow for use during controlled ventilation was determined in another eight ASA I-III patients when the minute volume to fresh gas ratio was greater than 1.5. In view of an increased arterial to end-tidal carbon dioxide partial pressure difference in patients in the first part of the study (1.03 kPa), normocapnia was defined as an end-tidal carbon dioxide partial pressure of 4.3 kPa. Normocapnia was achieved with a mean fresh gas flow of 66 ml kg(-1) min(-1), while 70 ml kg(-1) min(-1) produced mild hypocapnia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fresh gas requirements of an enclosed afferent reservoir breathing system during controlled ventilation in children.

An enclosed afferent reservoir breathing system (EAR) designed by Ohmeda was evaluated during anaesthesia with controlled ventilation in 104 healthy children. Carbon dioxide production and arterial carbon dioxide tension were measured in 12 children in order to determine the proportion of fresh gas (VF) involved in gas exchange. When the ratio of minute volume ventilation to fresh gas flow (VE:...

متن کامل

Enclosed afferent reservoir breathing systems. Description and clinical evaluation.

A new group of breathing systems, namely the Enclosed Afferent Reservoir (EAR) systems, is described. They allow for the selective elimination of alveolar gas in association with both spontaneous and controlled ventilation. A comparison with the Bain system in controlled ventilation demonstrates greater efficiency in eliminating carbon dioxide. A fresh gas flow (VF) of 70 ml kg-1 min-1 using an...

متن کامل

Fresh gas requirements of an enclosed afferent reservoir breathing system in anaesthetized, spontaneously breathing adults.

Using two methods of determining the onset of rebreathing, we have determined the minimum fresh gas flow rate (VF) of the Ohmeda enclosed afferent reservoir breathing system (EAR) in anaesthetized, spontaneously breathing adults. Rebreathing as defined by the Kain and Nunn criteria did not occur when the VF/VE ratio was greater than 0.70. A mathematical model was used to calculate the degree of...

متن کامل

Controlled ventilation with a Mapleson A (Magill) breathing system: reassessment using a lung model.

We have used a lung model to reassess the efficiency of the Magill attachment during controlled ventilation in which the pattern of ventilation, tidal volume and fresh gas flows were varied. Adjustment of the inspiratory:expiratory ratio to ensure a prolonged expiratory phase is recommended, to improve efficiency and predictability of the system, if its use is necessary for short periods during...

متن کامل

Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV

BACKGROUND Prolonged controlled mechanical ventilation depresses diaphragmatic efficiency. Assisted modes of ventilation should improve it. We assessed the impact of pressure support ventilation versus neurally adjusted ventilator assist on diaphragmatic efficiency. METHOD Patients previously ventilated with controlled mechanical ventilation for 72 hours or more were randomized to be ventilat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 66 6  شماره 

صفحات  -

تاریخ انتشار 1991