PURPOSE To study the mechanisms of pupillary block in eyes with occludable angle by ultrasound biomicroscopy. METHODS Initially, a pilot study of 13 eyes with acute primary angle-closure without medication was executed. Ultrasound biomicroscopy measurements of the angle, posterior chamber depth and iris thickness were performed in the temporal quadrant under light and dark conditions. Afterwards, ultrasound biomicroscopy measurements of iris-lens contact distance and iris-lens angle in the temporal quadrant and central anterior chamber depth were made in 32 eyes with acute primary angle-closure or intermittent primary angle-closure without medication, under light and dark conditions before and after laser peripheral iridectomy. RESULTS In the pilot study, a significant decrease in the angle as well as a significant increase in the iris thickness occurred when comparing light to dark conditions. Before and after laser peripheral iridectomy (second study), significant differences were found in iris-lens contact distance (P<0.001) and iris-lens angle (P<0.001) under light and dark conditions. Also, significant differences were found in light and dark conditions, before laser peripheral iridectomy, in iris-lens angle (P=0.005), and after laser peripheral iridectomy, in iris-lens contact distance (P<0.001). No significant change occurred with anterior chamber depth. CONCLUSIONS A decreased angle was correlated to an increase in iris thickness. After laser peripheral iridectomy, acute primary angle-closure or primary angle-closure eyes had an increased iris-lens contact distance and a decreased iris-lens angle. The anterior chamber depth did not change. These findings contradict the theory that pupillary block is the mechanism of acute primary angle-closure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia.

PURPOSE To report a case of bilateral glaucoma related to pseudophacomorphic mechanism in one eye and pupillary block in the other eye after Visian Implantable Collamer Lens (ICL, STAAR Surgical) insertion. METHODS A 44 year-old female with high myopia underwent bilateral ICL implantation of MICL12.6 after sulcus diameter measurements were performed by Pentacam. RESULTS Pseudophacomorphic g...

متن کامل

Pseudophakic pupillary block glaucoma in early postoperative period masquerading as endophthalmitis: Clinical features are important for differential diagnosis

Pseudo-phakic pupillary block glaucoma in postoperative period may mimic acute endophthalmitis. This article illustrates how clinical differentiation of pseudo-phakic pupillary block glaucoma from postoperative acute endophthalmitis was done as ultrasonography produced confusing results.

متن کامل

Ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by Soemmering's ring.

AIM To perform ultrasound biomicroscopic analysis of pseudophakic pupillary block glaucoma induced by lens capsule and a Soemmering's ring and its resolution, and to elucidate the pathophysiology of this glaucoma. METHODS A woman with pseudophakic pupillary block glaucoma underwent successful neodymium:YAG (Nd:YAG) laser photodisruption of the lens capsule through a laser iridotomised colobom...

متن کامل

Enhancing the Early Differential Diagnosis of Plateau Iris and Pupillary Block Using A-Scan Ultrasonography

PURPOSE To distinguish the frequently misdiagnosed plateau iris eyes from pupillary block group and normal group, we compared the ocular biometrical parameters of them by A-scan ultrasongraphy. METHODS In total, we retrospectively reviewed general characteristics and ocular findings including ocular biometric measurements of 71 normal, 39 plateau iris, and 83 pupillary block eyes. RESULTS T...

متن کامل

A New Method for On-Farm Euthanasia with Animal Welfare Considerations

Objective: Euthanasia of animals is a highly stressful situation for veterinarians and may be source of ethical dilemmas; also, it is very difficult to decide “which technique is more appropriate for the given situation”? The aim of this study was to describe a new humane method for on-farm euthanasia. Design: Pilot clinical trial. Animals: thirteen animals including three horses, six sheep ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 2010