Pelvic modelling and the comparison between plate position for double pelvic osteotomy using artificial cancellous bone and finite element analysis
نویسندگان
چکیده
BACKGROUND Finite element analysis was used to compare fixation methods for double pelvic osteotomy (DPO). Using 3D scanning a stereolithography (stl) image was produced of a canine pelvis and this was subsequently refined in computer aided design (CAD). Using the CAD files, the images were imported in MSC Marc software to produce a working finite element (FE) model with 3 dimensional tetrahedral elements with linear shaped functions. The dimensions of a precontoured pelvic osteotomy plate with eight screws and a twisted seven screw straight plate were used to build the 2 fixations implants for the FE models. An equivalent load of 300 N was applied progressively on all FE models in order to facilitate its convergence. The load was applied in a distributed manner on the femur-hip joint contact area in order to simulate the actual behavior of the joint. The aim of the present study was to analyze the difference in stiffness and behavior under loading between a lateral vs ventral plate fixation, with unlocked screws and different gap scenarios, for stabilization of a pelvic osteotomy using finite element analysis. RESULTS From both configurations the maximum displacement of the ventral plate with 7 screws without gap had a value of 1.988 mm, while in the DPO plate had a maximum displacement of 2.191 mm. The load applied for each of the different configurations studied when a gap of 1° was considered and also when a condition of no gap was considered. The ventral plate was stiffer than the lateral plate when a gap was not present. When the gap was closed in the ventral plate, the stiffness increased until a point that remained constant. CONCLUSIONS Ventral plate fixation can be as or more stiff as lateral plate fixation and provides flexible fixation. This behavior should reduce screw loosening. Using ventral plate fixation is recommended to reduce screw loosening or failure.
منابع مشابه
A Modified Triple Pelvic Osteotomy for the Treatment of Hip Hypoplasia
Background: The prevalence of hip dysplasia is 1 in 1000. Several pelvic osteotomy methods have been developed to prevent early osteoarthritis, such as triple osteotomy. In this study we are going to introduce our new technique that was done on 4 patients with favorable short-term results. Methods: Four patients underwent triple osteotomy and fixation using a reconstruction plate and early ...
متن کاملThree-dimensional reduction and finite element analysis improves the treatment of pelvic malunion reconstructive surgery
RATIONALE Pelvic malunion is a rare complication and is technically challenging to correct owing to the complex three-dimensional (3D) geometry of the pelvic girdle. Hence, precise preoperative planning is required to ensure appropriate correction. Reconstructive surgery is generally a 2- or 3-stage procedure, with transiliac osteotomy serving as an alternative to address limb length discrepanc...
متن کاملA structural numerical model for the optimization of double pelvic osteotomy in the early treatment of canine hip dysplasia.
BACKGROUND Double pelvic osteotomy (DPO) planning is usually performed by hip palpation, and on radiographic images which give a poor representation of the complex three-dimensional manoeuvre required during surgery. Furthermore, bone strains which play a crucial role cannot be foreseen. OBJECTIVE To support surgeons and designers with biomechanical guidelines through a virtual model that wou...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملComparison between Radial and Halbach Array PMLSM by Employing 2-D Electromagnetic Finite Element Analysis
The replacement of steam catapults with electromagnetic ones is becoming an overwhelming trend in aircraft launch systems. The Electromagnetic Aircraft Launch System (EMALS) offers significant benefits to the aircraft, ship, personnel, and operational capabilities. EMALS has such advantages as high thrust, good controllability, reusable, etc., as a launching motor, a double-side plate Permanent...
متن کامل