Continuous suture technique for freedom stentless valve: reduced crossclamp time.

نویسندگان

  • Sven Beholz
  • Simon Dushe
  • Wolfgang Konertz
چکیده

The Pericarbon Freedom stentless valve has shown excellent hemodynamics. A continuous suture technique at the inflow site may reduce cardiopulmonary bypass and crossclamp times and affect postoperative hemodynamics. In a prospective case-matched study, interrupted and continuous suture line techniques were used in 68 and 71 patients, respectively. Isolated valve replacement was performed in 70.4% of the continuous suture group and 67.6% of the interrupted suture group. Hemodynamic data were obtained by echocardiography (mean and peak gradients, regurgitation) at discharge and after 1 year. Overall mortality was 5.0% and due to non-valve-related causes. Bypass and crossclamp times were shorter by 22.4 and 20.6 min, respectively, in the continuous suture group. The suture technique at the inflow site did not result in significant differences in the mean (11.8 +/- 6.3 vs. 12.5 +/- 6.2 mm Hg) or peak gradients (21.0 +/- 9.6 vs. 22.0 +/- 10.9 mm Hg), or degree of regurgitation. Follow-up showed a further decrease in the gradients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.

BACKGROUND AND AIM OF THE STUDY The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. METHODS In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacem...

متن کامل

Recommendations for the implantation of the Pericarbon Freedom stentless valve.

Based on our experience of 1000 subcoronary implants of the Sorin Pericarbon Freedom stentless valve, we give recommendations for the exact implantation technique. This article illustrates basic issues in the implantation technique with respect to continuous and interrupted suture to enable beginners and experienced surgeons to avoid some of the pitfalls. Additional remarks about sizing and ear...

متن کامل

Operative technique and early hemodynamic results with the Freedom Solo valve.

BACKGROUND AND AIM OF THE STUDY Stentless aortic valve prostheses usually require two separate suture lines. The Freedom Solo valve (Sorin Group, Saluggia, Italy), by using a minimized implantation technique, requires only a single running suture line of 4-0 polypropylene. Herein are reported the surgical experience and early hemodynamic results obtained with this new valve. METHODS Following...

متن کامل

Stentless aortic valves. Current aspects

The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....

متن کامل

The Sorin Freedom SOLO stentless aortic valve: easier implantation technique with potentially less risk of complications.

Aortic valve replacement by bioprosthesis is increasingly being used. Among these, stentless bioprosthesis is becoming a valid choice due to its potential hemodynamic improvement. The Sorin Freedom SOLO stentless aortic valve (FS) (Sorin Biomedica Cardio, Saluggia, Italy) is widely used, with initial and midterm promising results. It is designed to be deployed in a straightforward manner in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Asian cardiovascular & thoracic annals

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2006