Development of an MR-compatible DOI-PET detector module

نویسندگان

  • Qingyang Wei
  • Shi Wang
  • Tianpeng Xu
  • Yunpeng Gao
  • Yaqiang Liu
  • Tianyu Ma
چکیده

Department of Electrical Engineering, Tsinghua University, Beijing, China Silicon Photomultiplier (SiPM) is a promising sensor for MR-compatible PET systems. In this paper, we developed a compact 2-layer DOI-PET detector. The top layer is a 15Ã15 LYSO array, and the crystal size is 2x2x7mm. The bottom layer is a 16Ã16 array with the same size crystals. There is half-crystal offset between two layers in both transverse directions. The detector is coupled to an 8Ã8 SiPM array (MicroFB-30035SMT, Sensl). Sixty-four channels of SiPMs are read out by an ASIC chip with in-chip multiplexing resistor networks in the form of two position and one energy analog signals, and are then converted to wave-form digital signals with 80 MHz 12-bit ADC chips. The energy is calculated by averaging the 3 points around the peak of the pulse. Flood images with two 22Na point sources irradiated on the top and at the bottom of the detector module were acquired. The results show that the detector module achieves good crystal identification capability in both layers with an average energy resolution of 17.1% at 511 keV.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a PET Insert for simultaneously small animal PET/MRI.

Division of Nuclear Technology and Applications, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China PET/MR is a new multi-modality imaging system which provide both structural and functional information with good soft tissue imaging ability and no ionizing radiation. In recent years, PET/MR is under major progress because of the development of silicon photomult...

متن کامل

Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

UNLABELLED PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. METHODS The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode ...

متن کامل

A novel, SiPM-array-based, monolithic scintillator detector for PET.

Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-se...

متن کامل

PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.

PURPOSE To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager. MATERIALS AND METHODS All animal experiments were performed in accordance with the University of Tübingen guidelines and the German law for the protection of animals. A compact lutetium oxyorthosilicat...

متن کامل

Development of PET insert for simultaneous PET/MR imaging of human brain

Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul, Korea Recently, there has been great interest on the development of combined PET/MR, which is a useful tool for both functional and anatomic imaging. The purpose of this study was to develop a MR compatible PET insert for simultaneous PET and MR imaging of human brain and to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015