Exploring infrared wavelength matrix-assisted laser desorption/ionization of proteins with delayed-extraction time-of-flight mass spectrometry.

نویسندگان

  • W Zhang
  • S Niu
  • B T Chait
چکیده

We report a study of the application of delayed extraction (DE) to infrared-wavelength matrix-assisted time-of-flight mass spectrometry (IR-MALDI-TOF-MS) of proteins. The shapes of the spectral peaks obtained with DE-IR-MALDI-MS are compared with those obtained from the same samples and matrix using continuous extraction (CE) IR-MALDI-MS. Application of DE results in significant improvements in the peak resolution, revealing spectral features (in proteins with molecular masses < 12 kDa) that were not resolved in the corresponding CE-IR-Maldi mass spectra. Particularly significant is a series of peaks on the high mass side of the protonated protein peaks that arise through replacement of protons by adventitious sodium ions in the sample. We deduced that these sodium replacement species are a significant contributor to the broad tails (and resulting peak asymmetries) that are a feature of the DE-IR-MALDI mass spectra of proteins with molecular masses > or = 17 kDa. The peak width reduction observed in IR-MALDI by DE suggests that, as in UV-MALDI, the initial velocity distribution for ions produced in the MALDI process contributes to the peak broadness in the CE mass spectra. In a systematic comparison between DE UV-MALDI and DE IR-MALDI, we determined that photochemical matrix adduction is present in UV-MALDI but absent in IR-MALDI. In addition, we find that protein ions produced by IR irradiation are less internally excited (i.e., cooler), exhibiting less fragmentation, more Na+ replacement and/or unspecified noncovalent adduction, and more heme adduction with apomyoglobin. Thus, IR-MALDI appears to be a softer means for producing gas-phase protein ions than is UV-MALDI. It will be of considerable practical interest to determine whether large protein ions produced by IR-MALDI are sufficiently cool to survive transport through reflecting TOF mass spectrometers (without loss of small neutral species such as H2O, NH3, and CO2) and the extended time periods required for detection by quadrupole ion trap and Fourier transform ion cyclotron resonance mass analyzers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved resolution in the detection of oligonucleotides up to 60-mers in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using pulsed-delayed extraction with a simple high voltage transistor switch.

Pulsed-delayed extraction using a simple high voltage transistor switch together with various sample purification approaches were used to enhance the resolution in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of oligonucleotides up to 60 bases long. This switch can provide a 0-3 kV voltage pulse with a 75 ns fall time. A resolution of 500-900 was ty...

متن کامل

DNA sequencing by delayed extraction-matrix-assisted laser desorption/ionization time of flight mass spectrometry.

Matrix-assisted laser desorption/ionization (MALDI) time of flight mass spectrometry was used to detect and order DNA fragments generated by Sanger dideoxy cycle sequencing. This was accomplished by improving the sensitivity and resolution of the MALDI method using a delayed ion extraction technique (DE-MALDI). The cycle sequencing chemistry was optimized to produce as much as 100 fmol of each ...

متن کامل

Fast and accurate identification of dermatophytes by matrix-assisted laser desorption ionization-time of flight mass spectrometry: validation in the clinical laboratory.

The performance of a matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) workflow using an extensive reference database for dermatophyte identification was evaluated on 176 clinical strains. Using a direct-deposit procedure after 3 incubation days yielded 40% correct identification. Both increasing incubation time and using an extraction procedure resulte...

متن کامل

Wavelength Dependence On The Level Of Post-Source Metastable Ion Decay Observed In Infrared Matrix-Assisted Laser Desorption Ionization.

The levels of post-source metastable ion decay (PSD) observed in several peptides and proteins ionized by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI TOF-MS) are measured utilizing both infrared (IR) and ultraviolet (UV) desorption wavelengths. A gridless deceleration ion optic is employed to temporally separate stable analyte ions from analyte metastable...

متن کامل

Verification of a Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Method for Diagnostic Identification of High-Consequence Bacterial Pathogens.

We examined the utility of a single matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry method for the identification of security-sensitive biological agents (risk group 3 bacterial pathogens). The goal was 2-fold: to verify a method for inclusion into our scope of accreditation, and to assess the biological safety of extractions. We developed our sample flo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 9 9  شماره 

صفحات  -

تاریخ انتشار 1998