Evaluation of the Perkins handheld applanation tonometer in horses and cattle
نویسندگان
چکیده
The objective of this study was to evaluate and validate the accuracy of the Perkins handheld applanation tonometer for measuring intraocular pressure (IOP) in horses and cattle. Both eyes of 10 adult horses and cattle were evaluated in a postmortem study. The eyes from 10 clinically normal adult horses and cattle were also examined after bilateral auriculopalpebral nerve block and topical anesthesia for an in vivo study. IOP was measured postmortem using direct manometry (measured with an aneroid manometer) and tonometry (measured with a Perkins handheld applanation tonometer). The correlation coefficients (r(2)) for the data from the postmortem manometry and Perkins tonometer study were 0.866 for horses and 0.864 for cattle. In the in vivo study, IOP in horses was 25.1 ± 2.9 mmHg (range 19.0~30.0 mmHg) as measured by manometry and 23.4 ± 3.2 mmHg (range 18.6~28.4 mmHg) according to tonometry. In cattle, IOP was found to be 19.7 ± 1.2 mmHg (range 18.0~22.0 mmHg) by manometry and 18.8 ± 1.7 mmHg (range 15.9~20.8 mmHg) by tonometry. There was a strong correlation between the IOP values obtained by direct ocular manometry and the tonometer in both horses and cattle. Our results demonstrate that the Perkins handheld tonometer could be an additional tool for accurately measuring IOP in equine and bovine eyes.
منابع مشابه
Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods
PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...
متن کاملPerkins hand-held applanation tonometer. A clinical evaluation.
MANY ophthalmologists measure intra-ocular pressure with the Goldmann tonometer. It is neither portable nor capable of being used with the patient supine, which is disadvantageous in glaucoma screening programmes when it is often necessary to examine sick patients in their homes. An applanation tonometer, which is portable and can be used with the patient supine, sitting, or even standing, has ...
متن کاملTwo-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry
BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...
متن کاملDiagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients.
BACKGROUND Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate...
متن کاملUse of the Perkins hand-held applanation tonometer in retinal detachment surgery.
The applanation method is generally accepted as being the most accurate for measuring intraocular pressure. Perkins (i965) described a hand-held portable applanation tonometer. Whitty (I969) reported his results using this tonometer: he found that readings with the hand applanator were slightly (I-I-5 mm.Hg) lower than those taken with the Haag-Streit tonometer, and he felt that this may have b...
متن کامل