The Characterization of a Piston Displacement-Type Flowmeter Calibration Facility and the Calibration and Use of Pulsed Output Type Flowmeters

نویسنده

  • G. E. Mattingly
چکیده

Critical measurement performance of fluid flowmeters requires proper and quantified verification data. These data should be generated using calibration and traceability techniques established for these verification purposes. In these calibration techniques, the calibration facility should be well-characterized and its components and performance properly traced to pertinent higher standards. The use of this calibrator to calibrate flowmeters should be appropriately established and the manner in which the calibrated flowmeter is used should be specified in accord with the conditions of the calibration. These three steps: 1) characterizing the calibration facility itself, 2) using the characterized facility to calibrate a flowmeter, and 3) using the calibrated flowmeter to make a measurement are described and the pertinent equations are given for an encoded-stroke, piston displacement-type calibrator and a pulsed output flowmeter. It is concluded that, given these equations and proper instrumentation of this type of calibrator, very high levels of performance can be attained and, in turn, these can be used to achieve high fluid flow rate measurement accuracy with pulsed output flowmeters.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydrocarbon Liquid Flow Calibration Service

This document provides a description of a 2 liter hydrocarbon liquid flow calibration standard operated by the National Institute of Standards and Technology (NIST) Fluid Metrology Group to provide flowmeter calibrations for customers. This facility uses a passive piston prover technique where fluid is driven by pumps while the measuring piston is pushed by the fluid over a measured length duri...

متن کامل

A Transient Electromagnetic Flowmeter and Calibration Facility

Flowmeter and Calibration Facility P.J. Lefebvre Naval Underwater Systems Center, Newport, R.1. An electromagnetic flowmeter was developed to measure transient flows at a data rate of 60 Hz. The approach taken was to develop suitable electronics to replace the electronics ofa commercially available electromagnetic flowmeter normally used W. W. Durgin for steady-state operation. Use of the comme...

متن کامل

Calibration and Standards in Flow Measurement

Calibration is defined as follows: ‘The set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards.’ It is important to recognize at the outset the definition of a ‘calibration’ and to note that the ‘comparison’ applies only to the condition...

متن کامل

A Circular Towing Tank for Calibrating Plankton - net Flowmeters

A specially designed circular towing tan~ was developed at the Northeast Fisheries Center (NEFC) for calibrating plankton-net flowmeters . ashore in order to provide more accurate volume estimates and to save valuable shipboard time. Results of a cross-calibration experiment with a flume in use at the Massachusetts Institute of Technology (MIT) demonstrated that calibration factors produced by ...

متن کامل

The Long Term Calibration Stability of Critical Flow Nozzles and Laminar Flowmeters

The National Institute of Standards and Technology (NIST) has performed calibrations of gas flowmeters using piston and bell provers for three decades. Most of the meters calibrated have been either critical flow nozzles or laminar flowmeters since these meter types are generally chosen as the working standards or transfer standards by other flow calibration laboratories. Often the same meters ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 97  شماره 

صفحات  -

تاریخ انتشار 1992