Reaction of plasmic degradation products of fibrinogen in the radioimmunoassay of human fibrinopeptide A.

نویسندگان

  • A Z Budzynski
  • V J Marder
  • S Sherry
چکیده

A radioimmunoassay (RIA) technique has been devised for the measurement of human fibrinopeptide A (FPA). The system utilizes rabbit antiserum to native human FPA and a synthetic fibrinopeptide, with tyrosine substituted for phenylanine in amino acid position 8. The test detects native human FPA at a concentration of 0.1 ng/ml, but does not cross react with human fibrinopeptide B or with fibrinopeptides A from canine, porcine, or bovine fibrinogen. Fibrinogen and chemical or plasmic degradation products with 2 moled of FPA per mole react fully in this test system. This includes the large-molecular-weight intermediate fragments X and Y and the NH2-terminal disulfide knot, and indicates that this antibody recognizes and reacts with FPA in the presence of the contiguous peptide structures present in fibrinogen. Fragment E, which is derived from the NH-2-terminal portion of fibrinogen, loses most of its FPA content after its liberation from its precursor derivative and reacts to a lesser extent in the RIA than do fragments X and Y. This correlated with the recovery of FPA-positive material from ultrafilitrates of extensive but not partial plasmic digests of fibrinogen. Although FPA immunoreactivity liberated from fibrinogen does not necessarily reflect thrombin activity and/or fibrin formation, only extensive plasmic degradation yields peptide material which reacts in this RIA system. This should not be a serious limitation to the application of the RIA in the detection of venous thrombosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasmic Degradation Products of Fibrinogen 759 Chromatography Electrophoresis

A radioimmunoassay (RIA) technique has been devised for the measurement of human fibrinopeptide A (PA). The system utilizes rabbit antiserum to native human PA and a synthetic fibrinopeptide, with tyrosine substituted for phenylanine in amino acid position 8. The test detects native human PA at a concentration of 0.1 ng/ml, but does not cross react with human flbrinopeptide B or with flbnnopept...

متن کامل

Fibrinogen in the Radioimmunoassay of Human Fibrinopeptide

A radioimmunoassay (RIA) technique has been devised for the measurement of human fibrinopeptide A (PA). The system utilizes rabbit antiserum to native human PA and a synthetic fibrinopeptide, with tyrosine substituted for phenylanine in amino acid position 8. The test detects native human PA at a concentration of 0.1 ng/ml, but does not cross react with human flbrinopeptide B or with flbnnopept...

متن کامل

Fibrinogen in the Radioimmunoassay of Human Fibrinopeptide A

A radioimmunoassay (RIA) technique has been devised for the measurement of human fibrinopeptide A (PA). The system utilizes rabbit antiserum to native human PA and a synthetic fibrinopeptide, with tyrosine substituted for phenylanine in amino acid position 8. The test detects native human PA at a concentration of 0.1 ng/ml, but does not cross react with human flbrinopeptide B or with flbnnopept...

متن کامل

Fibrinogen in the Radioimmunoassay of Human

A radioimmunoassay (RIA) technique has been devised for the measurement of human fibrinopeptide A (PA). The system utilizes rabbit antiserum to native human PA and a synthetic fibrinopeptide, with tyrosine substituted for phenylanine in amino acid position 8. The test detects native human PA at a concentration of 0.1 ng/ml, but does not cross react with human flbrinopeptide B or with flbnnopept...

متن کامل

Structure of plasmic degradation products of human fibrinogen. Fibrinopeptide and polypeptide chain analysis.

Direct determination of fibrinopeptides A and B in purified plasmic degradation products of human fibrinogen shows that fibrinogen and Fragments X and Y contain 2 moles of fibrinopeptide A per mole; Fragment E has approximately 0.3 mole of fibrinopeptide A per mole. Fibrinopeptide B is present in only trace amount in some Fragment X preparations and is absent from Fragments Y and E. Fragment D ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Blood

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 1975