Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth
نویسندگان
چکیده
Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan) and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA) for measuring central corneal thickness (CCT), anterior chamber depth (ACD), and aqueous depth (AD). Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using paired t-tests, Bland-Altman plots, and 95% limits of agreement (LoA). Results. The mean CCT, ACD, and AD measured by AL-Scan were 538.59 ± 27.37 μm, 3.70 ± 0.30 mm, and 3.16 ± 0.30 mm, respectively. The mean values obtained by the Visante OCT were 536.14 ± 26.61 μm for CCT, 3.71 ± 0.29 mm for ACD, and 3.17 ± 0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference = 2.45 ± 6.07 μm, P < 0.05). The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between -9.44 and 14.35 μm, -0.15 and 0.12 mm, and -0.15 and 0.12 mm, respectively. Conclusions. Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.
منابع مشابه
Submicrometer precision biometry of the anterior segment of the human eye.
PURPOSE To demonstrate the feasibility of measuring the anterior structures of the human eye by partial coherence interferometry and to determine its precision for eyes under normal and cycloplegic conditions. METHODS The dual-beam version of partial coherence interferometry, a recently developed noninvasive optical ranging technique, enables high resolution measurements of several intraocula...
متن کاملChanges in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
The aim of this study was to investigate changes in the anterior segment of the eye after cycloplegia. A biometer combined with swept-source optical coherence tomography (SSOCT) was used for measurements. Patients with strabismus or amblyopia who underwent cycloplegia were included. The axial length, central corneal thickness, anterior chamber depth, and lens thickness were measured with the bi...
متن کاملBiometry of the cornea and anterior chamber in chinese eyes: an anterior segment optical coherence tomography study.
PURPOSE. To investigate the normative data of corneal and anterior segment biometric parameters and their associations in Chinese adults, for use in preoperative assessment for corneal and anterior segment surgery. METHODS. This cross-sectional, population-based study included 750 subjects aged > or =50 years. The subjects underwent an ophthalmic examination including imaging with anterior segm...
متن کاملOcular biometric characteristics during the menstrual cycle
PURPOSE To determine the ocular biometric characteristics during the menstrual cycle using the optical low-coherence reflectometry (OLCR) biometry. METHODS Twenty-two healthy women between the ages of 19 and 36 years with regular menstrual cycles were enrolled in this prospective study. Subjects with irregular menstrual cycles, those taking contraceptive pills, those with a history of ocular ...
متن کاملFull anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.
We demonstrate an extended-imaging-range anterior-segment optical coherence tomography (eAS-OCT) system for the biometric assessment of full AS in human eye. This newly developed eAS-OCT operating at 1340-nm wavelength band is simultaneously capable of an imaging speed of 120 kHz A-line scan rate, an axial resolution of 7.2 μm, and an extended imaging range of up to 16 mm in air. Imaging result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016