Impact of stent surface on thrombogenicity and vascular healing: a comparative analysis of metallic and polymeric surfaces.

نویسندگان

  • Michael J Eppihimer
  • Natalia Sushkova
  • Jessica L Grimsby
  • Natalia Efimova
  • Wang Kai
  • Steve Larson
  • Bruce Forsyth
  • Barbara A Huibregtse
  • Keith D Dawkins
  • Gregory J Wilson
  • Juan F Granada
چکیده

BACKGROUND Emerging drug-eluting stent technologies are evolving toward the elimination of polymeric component used as the method for modulating drug delivery. Although this technological approach seems to be biologically appealing, the impact of durable polymers and metallic stent surfaces on vascular healing remains unclear. In the present study, we aimed to compare the independent effect of a durable polymer and a metallic stent surface on thrombogenicity and endothelial cell coverage using different in vitro and in vivo experimental models. METHODS AND RESULTS Platinum chromium (PtCr) and polyvinylidene fluoride-co-hexafluoropropene (PVDF-HFP)-coated surfaces were evaluated in this study. Thrombogenicity was assessed by exposing all surfaces to human blood under shear flow conditions. The inflammatory potential of the material was evaluated by measuring cytokine release from THP-1 cells exposed to all surfaces for 24 hours. Endothelial cell coverage was evaluated by detection of CD31 after the stents were exposed to human coronary artery endothelial cells for ≤ 14 days. Platelet adhesion (P<0.01) and activation (P=0.03) on PVDF-HFP were greater than on PtCr. In vivo, PVDF-HFP revealed more neointimal area (P<0.01) and residual parastrut fibrin (P=0.01) at 30 days compared with PtCr. PtCr displayed higher endothelialization rates and higher vascular endothelial-cadherin expression at 7 and 14 days (P=0.02) compared with PVDF-HFP. CONCLUSIONS Thrombogenicity and vascular healing differ among metallic and polymeric stent surfaces. PVDF-HFP exhibits higher degrees of platelet activation-adhesion and thrombus accumulation in vivo compared with PtCr. PtCr displayed higher degrees of endothelial surface coverage compared with PVDF-HFP surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.

BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...

متن کامل

Surface Modification of Biodegradable Polymers towards Better Biocompatibility and Lower Thrombogenicity

PURPOSE Drug-eluting stents (DES) based on permanent polymeric coating matrices have been introduced to overcome the in stent restenosis associated with bare metal stents (BMS). A further step was the development of DES with biodegradable polymeric coatings to address the risk of thrombosis associated with first-generation DES. In this study we evaluate the biocompatibility of biodegradable pol...

متن کامل

Comparison of acute thrombogenicity for metallic and polymeric bioabsorbable scaffolds in a porcine arteriovenous shunt model

number: Euro17A-OP0628 Abstract type: Oral Presentation Reference: This abstract was presented at EuroPCR 2017, 16-19 May 2017, Paris Link: https://abstractbook.pcronline.com/export/pdf/id/628 Published on: 16 May 2017 Comparison of acute thrombogenicity for metallic and polymeric bioabsorbable scaffolds in a porcine arteriovenous shunt model LIPINSKI M.(1)ACAMPADO , E.(2)CHENG , Q.(2)ADAMS , L...

متن کامل

Microvascular endothelial cell sodding of 1-mm expanded polytetrafluoroethylene vascular grafts.

The formation of an endothelial cell lining on the inner surface of polymeric grafts may reduce the inherent thrombogenicity of synthetic implants. Endothelial cell transplantation onto the luminal surface of grafts has been suggested as one method of creating new endothelial cell linings on grafts. The purpose of this study was to morphologically evaluate the very early events of healing (betw...

متن کامل

The Study of Collagen Immobilization on a Novel Nanocomposite to Enhance Cell Adhesion and Growth

Background: Surface properties of a biomaterial could be critical in determining biomaterial’s biocompatibility due to the fact that the first interactions between the biological environment and artificial materials are most likely occurred at material’s surface. In this study, the surface properties of a new nanocomposite (NC) polymeric material were modified by combining plasma treatment and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2013