Validation and Comparison of Accelerometers Worn on the Hip, Thigh, and Wrists for Measuring Physical Activity and Sedentary Behavior
نویسندگان
چکیده
Background Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. Objective To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-intensity PA [LPA], and moderate- to vigorous-intensity PA [MVPA]) and breaks in SB. Methods Forty young adults (21 female; age 22.0 ± 4.2 years) participated in a 90-minute semi-structured protocol, performing 13 activities (three sedentary, 10 non-sedentary) for 3-10 minutes each. Participants chose activity order, duration, and intensity. Direct observation (DO) was used as a criterion measure of PA intensity category, and transitions from SB to a non-sedentary activity were breaks in SB. Participants wore four accelerometers (right hip, right thigh, and both wrists), and a machine learning model was created for each accelerometer to predict PA intensity category. Sensitivity and specificity for PA intensity category classification were calculated and compared across accelerometers using repeated measures analysis of variance, and the number of breaks in SB was compared using repeated measures analysis of variance. Results Sensitivity and specificity values for the thigh-worn accelerometer were higher than for wrist- or hip-worn accelerometers, > 99% for all PA intensity categories. Sensitivity and specificity for the hip-worn accelerometer were 87-95% and 93-97%. The left wrist-worn accelerometer had sensitivities and specificities of > 97% for SB and LPA and 91-95% for MVPA, whereas the right wrist-worn accelerometer had sensitivities and specificities of 93-99% for SB and LPA but 67-84% for MVPA. The thigh-worn accelerometer had high accuracy for breaks in SB; all other accelerometers overestimated breaks in SB. Conclusion Coupled with machine learning modeling, the thigh-worn accelerometer should be considered when objectively assessing PA and SB.
منابع مشابه
Calibration and Validation of a Wrist- and Hip-Worn Actigraph Accelerometer in 4-Year-Old Children
INTRODUCTION To determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children. METHODS In total 30 children (49 months, SD 3.7) were recruited from five preschools in Stockholm. Equipped wit...
متن کاملValidation of a Novel Device to Measure and Provide Feedback on Sedentary Behavior
PURPOSE Pedometers, which enable self-monitoring of step counts, are effective in facilitating increases in physical activity. Similar devices which provide real-time feedback on sedentary (sitting) behavior are limited. This study aimed to develop and validate a novel device-the SitFIT-which could accurately measure and provide feedback on sedentary behavior and physical activity. METHODS Th...
متن کاملValidation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
BACKGROUND Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. METHODS Twe...
متن کاملIntensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches
OBJECTIVES (1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics. METHOD...
متن کاملValidation of the Vivago
Background: Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago ® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. Methods: Tw...
متن کامل