Influence of droplet geometry on the coalescence of low viscosity drops.
نویسندگان
چکیده
The coalescence of water drops on a substrate is studied experimentally. We focus on the rapid growth of the bridge connecting the two drops, which very quickly after contact ensues from a balance of surface tension and liquid inertia. For drops with contact angles below 90°, we find that the bridge grows with a self-similar dynamics that is characterized by a height h~t(2/3). By contrast, the geometry of coalescence changes dramatically for contact angles at 90°, for which we observe h~t(1/2), just as for freely suspended spherical drops in the inertial regime. We present a geometric model that quantitatively captures the transition from 2/3 to 1/2 exponent, and unifies the inertial coalescence of sessile drops and freely suspended drops.
منابع مشابه
Lattice Boltzmann Simulation of Deformation and Breakup of a Droplet under Gravity Force Using Interparticle Potential Model
Abstract In this paper interparticle potential model of the lattice Boltzmann method (LBM) is used to simulate deformation and breakup of a falling droplet under gravity force. First this model is applied to ensure that the surface tension effect is properly implemented in this model. Two tests have been considered. First, it has been checked an initial square drop in a 2D domain can freely def...
متن کاملThe Influence of Bicomponent Mixed Surfactants on Drop/Interface Coalescence
Effects of binary mixtures of ionic/nonionic (sodium dodecyl sulfate/2-heptanol or 1-decanol) and nonionic/nonionic surfactants (2-heptnol/1-decanol) on drop/interface coalescence of water drops in a continuous n-heptane phase were examined. The drop size reduced appreciably and the multi-step coalescence was suppressed finally as the concentration of each of the constituting components</em...
متن کاملCoalescence in low-viscosity liquids.
The expected universal dynamics associated with the initial stage of droplet coalescence are difficult to study visually due to the rapid motion of the liquid and the awkward viewing geometry. Here we employ an electrical method to study the coalescence of two low-viscosity droplets at early times. We measure the growth dynamics of the bridge connecting the two droplets and observe a new asympt...
متن کاملDroplet Breakup in Flow Past an Obstacle: A Capillary Instability Due to Permeability Variations
In multiphase flow in confined geometries an elementary event concerns the interaction of a droplet with an obstacle. As a model of this configuration we study the collision of a droplet with a circular post that spans a significant fraction of the cross section of a microfluidic channel. We demonstrate that there exist conditions for which a drop moves completely around the obstacle without br...
متن کاملINVESTIGATION OF WATER DROPLET COALESCENCE by one
INTRODUCTION ILLUSTRATIONS CHAPTER I 1.1 1.2 1.3 COALESCENCE OF DISTILLED WATER DROPS Introduction Experimental Methods Experimental Results a) Dimple stability of water drops b) Effects of relative humidity and Impact velocity on coalescence c) Interference patterns for colliding water ii iii vii 1 1 2 6 6 drops 8 d) Retardation of water drop evaporation 13 e) Electrical effects on dimpling 14...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 111 14 شماره
صفحات -
تاریخ انتشار 2013