BACKGROUND Glanzmann thrombasthenia (GT) is a rare inherited platelet disorder that is characterized by spontaneous or postprocedural bleeding. The diagnosis of GT depends on identifying the dysfunction of the platelets. AIM The aim of this study was to compare a whole blood impedance Multiplate analyzer (MEA) with the standard method, light transmission aggregometry (LTA) in diagnosis of GT. METHODS Fifteen patients with GT were assessed on MEA and LTA using arachidonic acid (ASPI: 15 mm), (TRAP: 1 mm), collagen (100 μg/mL), ADP (0.2 mm), and ristocetin (Risto: 10 mg/mL). Whole blood samples were collected in sodium citrate and hirudin vacuum, blood collection tubes and tested within 4 h. Platelet-rich plasma was used for LTA using platelet agonists (ristocetin 1.5 mg/mL) (arachidonic acid 0.5 mg/mL) (ADP 2.5 mg/mL) and (collagen 1 mg/mL). RESULTS The platelet count and PFA-100 results were (average and SD) 319 ± 93 × 10(9) L and 252 ± 34 s, respectively. Flow cytometry analysis showed that all samples are positive for CD42a and CD42b, whereas 9/15 samples were negative for CD61 and CD41. The other six patients had either partial or full expression of CD61/CD41. Aggregation analysis using both methods showed that all samples had no aggregation response to any of the agonists used apart from six samples which, using only the MEA, showed minimal aggregation in response to collagen (average = 14.3 ± 7 μg, which may suggest ability to detect qualitative abnormality of GPIIb/IIIa). CONCLUSION These results suggest that the MEA is sensitive for the detection of Glanzmann thrombasthenia. Furthermore, MEA may also be able to differentiate between the subtypes of Glanzmann thrombasthenia.
منابع مشابه
Influence of the sample anticoagulant on the measurements of impedance aggregometry in cardiac surgery
BACKGROUND The standard method of assessment of platelet function is represented by light transmission aggregometry (LTA), performed in citrated platelet-rich plasma (PRP). With LTA, decrease and subsequent post-cardiopulmonary bypass (CPB) recovery of platelet function have been reported during cardiac surgery. Multiple electrode aggregometry (MEA) may be used as point-of-care method to monito...
متن کاملMicroparticle Formation and Platelet Shrinkage in Type-I Glanzmman Thrombasthenia Platelets
Background: Activated normal platelets undergo many biochemical and morphological changes, some of which are apoptotic. Platelet derived microparticles and shrinked platelets as hallmark of platelet activation and apoptosis disperse surfaces containing procoagulant activity around injured vessels and tissues. This study was conducted to determine microparticles formation and platelet shrinkage ...
متن کاملGlanzmann Thrombasthenia: A Clinicopathological Profile.
OBJECTIVE To describe the clinical presentation of patients with Glanzmann's thrombasthenia (GT) and evaluate their diagnostic, clinical, and laboratory parameters including platelet aggregometry. STUDY DESIGN Descriptive study. PLACE AND DURATION OF STUDY Department of Hematology and Blood Transfusion, The Children Hospital and Institute of Child Health, Lahore, from January 2006 to Decemb...
متن کاملPlatelet reactivity after clopidogrel treatment assessed with point-of-care analysis and early drug-eluting stent thrombosis.
OBJECTIVES The aim of this prospective trial was to assess whether platelet reactivity to clopidogrel assessed with multiple electrode platelet aggregometry (MEA) correlates with the risk of early drug-eluting stent thrombosis (ST). BACKGROUND Studies using light transmission aggregometry (LTA) have shown that insufficient suppression of platelet reactivity to adenosine diphosphate (ADP) afte...
متن کاملWhole blood impedance aggregometry as a biomarker for the diagnosis and prognosis of severe sepsis
INTRODUCTION Sepsis leads to an activation of the immune system and hemostatis. However, studies on platelet aggregation in severe sepsis using impedance aggregometry have not been performed and the diagnostic and prognostic capabilities are unknown. In the present study we hypothesized that impedance aggregometry findings might serve as a biomarker for the diagnosis and prognosis of severe sep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of laboratory hematology
دوره 37 4 شماره
صفحات -
تاریخ انتشار 2015