Early implant failures in patients treated with Brånemark System titanium dental implants: a retrospective study.
نویسندگان
چکیده
Implant failure has been associated with factors such as poor bone quality, insufficient bone volume, implant instability, unfavorable implant loading, and smoking habits. Infections and host responses may also be important factors in dental implant failure. The objectives of the present study were to identify various explanatory factors associated with titanium implant failure. Forty subjects with stage 1 non-osseointegrated titanium dental implants (NOTI) ad modum Brånemark and 40 age- and gender-matched control subjects with successfully osseointegrated titanium implants (SOTI) were studied. Clinical data and gamma G immunoglobulin (IgG) antibody titers were studied. An independent t test revealed that significantly longer implants were placed in subjects with SOTI (P < .05). Statistically significant differences in bone shape and resorption (BSR) scores were found between SOTI and NOTI (P < .05). Logistic regression analysis identified 3 significant explanatory outcome variables: serum antibody avidity scores for Bacteroides forsythus (P < .0001), serum antibody titers to Staphylococcus aureus (P < .001), and the BSR scores (P < .05). Antibody avidity to B forsythus and antibody titer to S aureus were therefore the 2 most important factors associated with early implant failures and with a significant predictive ability. This indicates that immunologic factors are involved in osseointegration.
منابع مشابه
Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study
Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
متن کاملImmediate and early function of Brånemark System implants placed in the esthetic zone: a 1-year prospective clinical multicenter study.
BACKGROUND Immediate/early implant function means great benefits for patients and therapists because treatment time and cost can be substantially reduced. This concept has become an accepted alternative for complete arch fixed restorations in the mandible, and clinical documentation is emerging for other indications. PURPOSE The purpose of this prospective clinical multicenter study was to ev...
متن کاملA clinical report on the 18-month cumulative survival rates of implants and implant prostheses with an internal connection implant system.
Titanium implants have been successful in both dentulous and edentulous patients. The original Brånemark titanium implants were introduced with external hex connections between implants and abutments. Successes and failures/complications with both the biology and mechanics of this connection system have been reported. In an attempt to improve the predictability and success of implant/abutment c...
متن کاملCORROSION BEHAVIOR OF BIOACTIVATED TITANIUM DENTAL IMPLANT USING DIFFERENT CHEMICAL METHODS
At the past, damaged tissue was removed from the body of patients. But now tissue regeneration using scaffolds and implants are used to repair the damaged tissue and organs. Besides of the mechanical properties of metallic biomaterials, they suffer from bioinertness. Using some surface treatment techniques, the bioactivity and also corrosion resistance of titanium implants could be improved. In...
متن کاملImmediate function of Brånemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up.
BACKGROUND Immediate implant function is a psychological benefit for the patient and makes a substantial reduction in treatment cost possible. Currently, immediate function using Brånemark implants has become an accepted alternative for complete-arch fixed restorations in mandibles and for overdenture support for some other screw-shaped implants. Clinical documentation is lacking for other appl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 16 2 شماره
صفحات -
تاریخ انتشار 2001