Improved Leg Tracking Considering Gait Phase and Spline-Based Interpolation during Turning Motion in Walk Tests
نویسندگان
چکیده
Falling is a common problem in the growing elderly population, and fall-risk assessment systems are needed for community-based fall prevention programs. In particular, the timed up and go test (TUG) is the clinical test most often used to evaluate elderly individual ambulatory ability in many clinical institutions or local communities. This study presents an improved leg tracking method using a laser range sensor (LRS) for a gait measurement system to evaluate the motor function in walk tests, such as the TUG. The system tracks both legs and measures the trajectory of both legs. However, both legs might be close to each other, and one leg might be hidden from the sensor. This is especially the case during the turning motion in the TUG, where the time that a leg is hidden from the LRS is longer than that during straight walking and the moving direction rapidly changes. These situations are likely to lead to false tracking and deteriorate the measurement accuracy of the leg positions. To solve these problems, a novel data association considering gait phase and a Catmull-Rom spline-based interpolation during the occlusion are proposed. From the experimental results with young people, we confirm that the proposed methods can reduce the chances of false tracking. In addition, we verify the measurement accuracy of the leg trajectory compared to a three-dimensional motion analysis system (VICON).
منابع مشابه
Changes in Gait Pattern During Smartphone and Tablet Use
Objectives: There exists no study concerning gait pattern while engaging in dual-task activities on different sizes of mobile devices. The present study aimed to compare gait patterns during normal walking, walking with smartphone use, and walking with tablet use. Methods: Seventeen healthy female participants with an age range of 19-24 years (mean±SD age: 20.29±1.61 years, weight: 49.82±4.46...
متن کاملاثر قطع عضو همیپلویکتومی بر کینماتیک و نیروی تولیدی عضلات اندام تحتانی حین راه رفتن با پروتز کانادین؛ گزارش موردی
Objective Hemipelvectomy amputation is a surgical procedure in which the lower limb and a portion of pelvic are removed. There are a few studies on the performance of this group of patients while walking. The aim of this paper was to evaluate the effect of hemipelvectomy amputation on kinematics and muscle force generation of the lower limb while walking with Canadian prosthesis. Materials & M...
متن کاملAnkle Angles during Step Turn and Straight Walk: Implications for the Design of a Steerable Ankle-foot Prosthetic Robot
This article compares the three-dimensional angles of the ankle during step turn and straight walking. We used an infrared camera system (Qualisys Oqus ®) to track the trajectories and angles of the foot and leg at different stages of the gait. The range of motion (ROM) of the ankle during stance periods was estimated for both straight step and step turn. The duration of combined phases of heel...
متن کاملUsing ambulatory virtual environments for the assessment of functional gait impairment: a proof-of-concept study.
This study aimed to demonstrate the sensitivity of virtual reality (VR)/motion tracking to detect global functional gait impairment resulting from an emulated knee disability as a prelude to describing mobility changes following lower limb injury/treatment. Participants walked in a figure-8 around two virtual posts placed 6m apart while viewing the computer-generated environment in a helmet-mou...
متن کاملTrajectory planning for smooth transition of a biped robot
interpolation based trajectory planning method which is aiming to achieve smooth biped swing leg trajectory by reducing the instant velocity change which occurs at the time of collision of the biped swing leg with the ground. We first characterize the bipedal walking cycle and point out some major issues that need to be addressed to plan a continuous swing leg trajectory by using the concept of...
متن کامل