Real-time tumor tracking during VMAT radiotherapy treatments based on 2D/3D registration using CBCT projections
نویسندگان
چکیده
Rotational radiotherapy treatments such as volumetric modulated arc therapy (VMAT) can have superior overall quality while having shorter delivery time with respect to conventional intensity modulated radiotherapy (IMRT). As with conventional treatments, intrafractional tumor motion is a major source of uncertainty in dose application. To ensure full tumor coverage the planning target volume (PTV) margins are enlarged. Tumor tracking using intensity based 2D/3D registration can reduce uncertainty and would enable margin reduction. The challenge for full arc rotational treatments is the poor tumor visibility at certain irradiation angles. In this work we investigate the feasibility of tumor tracking in VMAT treatments with partial arcs where the tumor is well visible. For three patients, we determined for which subset of angles it was possible to track the tumor using raw projections from CBCT acquisition. We then generated VMAT plans with the obtained partial arcs. Full arc VMAT plans were used as benchmark. For all cases is was possible to track the tumor in two arcs of about 90 degrees, typically with imaging around anterior-posterior (AP) or posterior-anterior (PA) projections. The plans with the partial arcs were clinically comparable to the plans with full arc in terms of target coverage and OAR sparing. The results indicate the feasibility of partial arc VMAT treatments with tumor tracking. Based on this we will investigate generation of plans with reduced PTV margins. These treatments could be delivered by gating the LINAC beam if the tumor motion exceeds a certain margin.
منابع مشابه
A feasibility study on the use of MV-CBCT images for urgent palliative treatment planning
Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملTarget localization of 3D versus 4D cone beam computed tomography in lipiodol-guided stereotactic radiotherapy of hepatocellular carcinomas
BACKGROUND Aim of this study was to comparatively evaluate the accuracy of respiration-correlated (4D) and uncorrelated (3D) cone beam computed tomography (CBCT) in localizing lipiodolized hepatocellular carcinomas during stereotactic body radiotherapy (SBRT). METHODS 4D-CBCT scans of eighteen HCCs were acquired during free-breathing SBRT following trans-arterial chemo-embolization (TACE) wit...
متن کاملLung tumor motion reproducibility for five patients who received four-fraction VMAT stereotactic ablative body radiotherapy under constrained breathing conditions: a preliminary study
Dear Editor, Several different approaches have been applied to stereotactic hypofractionated radiotherapy for lung tumors, including free breathing, breath-hold, gating, and tracking. Negoro et al. reported that abdominal compression reduced the movement of lung tumors (thereby possibly reducing treatment uncertainty), with portal fluoroscopy being used to measure the tumor movement [1]. Heinze...
متن کاملRadiotherapy Current Awareness Bulletin January 2017
To quantify the performance of the Clarity ultrasound (US) imaging system (Elekta AB, Stockholm, Sweden) for real-time dynamic multileaf collimator (MLC) tracking. The Clarity calibration and quality assurance phantom was mounted on a motion platform moving with a periodic sine wave trajectory. The detected position of a 30 mm hypoechogenic sphere within the phantom was continuously reported vi...
متن کامل