Certification of NIST standard reference material 2389a, amino acids in 0.1 mol/L HCl--quantification by ID LC-MS/MS.
نویسندگان
چکیده
An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.
منابع مشابه
Improved reference measurement method for hemoglobin A1c by use of liquid chromatography-isotope dilution-tandem mass spectrometry.
We have developed an improved reference measurement method for hemoglobin A1c (Hb A1c) 1 based on liquid chromatography–isotope dilution–tandem mass spectrometry (LC-ID-MS/MS) with traceability to the SI unit. The method has a small measurement uncertainty (MU) and gives results in good agreement with the accuracy-based IFCC reference method. Kaiser et al. (1 ) demonstrated the possibility of u...
متن کاملComparison of orthogonal liquid and gas chromatography-mass spectrometry platforms for the determination of amino acid concentrations in human plasma.
Concentrations of amino acids in a human plasma pool were determined using four independent quantification methods. Orthogonal separation schemes (LC, GC, or GC x GC) and detection systems (triple quadrupole or time-of-flight mass spectrometry) are shown to demonstrate excellent consistency among platforms for quantifying 18 amino acids in NIST Standard Reference Material (SRM) 1950 Metabolites...
متن کاملReference measurement procedure for total glycerides by isotope dilution GC-MS.
BACKGROUND The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an...
متن کاملMethods for the separation and quantification of arsenic species in SRM 2669: arsenic species in frozen human urine.
Two independent liquid chromatography inductively coupled plasma-mass spectrometry (LC/ICP-MS) methods for the separation of arsenic species in urine have been developed with quantification by standard additions. Seven arsenic species have been quantified in a new NIST frozen human urine Standard Reference Material (SRM) 2669 Arsenic Species in Frozen Human Urine, Levels 1 and 2. The species me...
متن کاملA quantitative LC-MS/MS method for comparative analysis of capture-antibody affinity toward protein antigens.
A mass spectrometry-based antibody selection procedure was developed to evaluate optimal 'capture' monoclonal antibodies that can be used in a variety of analytical measurement applications. The isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) methodology is based on the use of multiple-reaction monitoring of tryptic peptide fragments derived from protein antigens. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 397 2 شماره
صفحات -
تاریخ انتشار 2010