Total femoral replacement for salvage of periprosthetic fractures.

نویسندگان

  • Nicholas D Clement
  • Deborah MacDonald
  • Issaq Ahmed
  • James T Patton
  • Colin R Howie
چکیده

Patients with complex periprosthetic fracture patterns of the femur may ultimately require amputation. Some authors have described the use of mega-endoprostheses as a salvage procedure. This study reports functional outcome, complications, and implant and patient survival after total femoral replacement (TFR) for salvage of periprosthetic fracture of the femur. A prospective database of 20 consecutive patients who underwent TFR for salvage of a periprosthetic fracture was compiled. Patient demographics, mobility information, and preoperative and postoperative Short Form 12-item Survey (SF-12) and 1-year Toronto Extremity Salvage Score (TESS) data were recorded. Postoperative complications were obtained from the hospital database and patient medical notes. One patient was lost to follow-up and was excluded from analysis. The study included 8 men and 11 women, with a mean age of 68.4 years. No significant difference was noted in the prefracture physical (4.4; P=.13) or mental (0.3; P=.78) component scores of the SF-12 compared with 1-year scores. The TESS at 1 year was 69%. However, patients were more likely to require a walking aid postoperatively (P<.0001). One-fourth of the patients had a postoperative medical complication. In addition, 1 patient had a dislocation and 2 patients had a periprosthetic infection. The implant survival rate was 86% at 10 years; however, the 10-year mortality rate was 58%. Although TFR for salvage of a periprosthetic fracture of the femur offers good functional outcome and implant survival, it is at the expense of postoperative complications, and TFR is associated with a high long-term mortality rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence and risk factors for periprosthetic fracture in older recipients of total hip replacement: a cohort study

BACKGROUND The growing utilization of total joint replacement will increase the frequency of its complications, including periprosthetic fracture. The prevalence and risk factors of periprosthetic fracture require further study, particularly over the course of long-term follow-up. The objective of this study was to estimate the prevalence and risk factors for periprosthetic fractures occurring ...

متن کامل

A biomechanical evaluation of the interprosthetic distance as a risk factor for periprosthetic fractures of the femur: does the gap distance matter?

Introduction The treatment of femoral fractures between a proximal and distal prosthetic stem is expected to become a major challenge because of the increasing life expectancy and the rising prevalence of osteoporotic fractures, Total Hip (THA) and Total Knee Arthroplasties (TKA). Although orthopedic surgeons intuitively consider a decreased interprosthetic gap distance as an important risk fac...

متن کامل

Mennen plate fixation for the treatment of periprosthetic femoral fractures.

BACKGROUND The management of periprosthetic femoral fractures after total hip and knee replacement remains difficult and controversial. This study was performed to determine the results of Mennen plate fixation for the treatment of periprosthetic femoral fractures. METHODS This retrospective multicenter study consists of a review of a consecutive series of thirty-five patients in whom a total...

متن کامل

Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with pr...

متن کامل

Antibiotic-impregnated Cement Plate for the Treatment of Infected Periprosthetic Femoral Fracture after Cementless Total Hip Arthroplasty - A Case Report -

Copyright c 2012 by Korean Hip Society 245 Periprosthetic femoral fracture is a problematic complication of total hip arthroplasty (THA). Although treatment protocols for periprosthetic femoral fracture have been reported, treatment protocols for periprosthetic fracture with accompanying infection have rarely been published. When these two complications occur together, it becomes more difficult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 9  شماره 

صفحات  -

تاریخ انتشار 2014