Hepatic Mitochondrial Function Analysis Using Needle Liver Biopsy Samples

نویسندگان

  • Michael J. J. Chu
  • Anthony R. J. Phillips
  • Alexander W. G. Hosking
  • Julia R. MacDonald
  • Adam S. J. R. Bartlett
  • Anthony J. R. Hickey
چکیده

BACKGROUNDS AND AIM Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg) obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean). Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each) showed low coefficient of variation (<10%) in measurements of State-III respiration, electron transport chain (ETC) capacity and respiratory control ratio (RCR). Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Needle biopsy for hepatic vitamin A levels in lions (Panthera leo).

Hypovitaminosis A (HA)-related skull malformations resulting in neurologic abnormalities and death have been, and still are, reported in captive lions (Panthera leo) worldwide. Liver vitamin A (VA) concentration is the most reliable indicator of animals' VA status, and its assessment is essential in prevention and treatment of HA in lions. A percutaneous needle liver biopsy using high-performan...

متن کامل

Transjugular liver biopsy: a comparison of aspiration and trucut techniques.

The results of 67 transjugular liver biopsies are described. Two failures were encountered due to inability to pass the needle into acutely angulated hepatic veins. Thirty-four patients underwent a liver aspiration biopsy using a Colapinto needle, while the remainder were biopsied using a trucut needle. The success rate with the Colapinto needle was 68% and with the trucut model, 97%. Capsular ...

متن کامل

Laparoscopic liver biopsy in the diagnosis of hepatic epithelioid hemangioendothelioma: A case report

Hepatic epithelioid hemangioendothelioma (HEH) is a rare vascular tumor of the liver, and its definitive diagnosis is completely dependent on histopathological verification. In the present study, we report the case of a patient whose percutaneous liver biopsy failed to reveal a diagnosis of HEH, twice, and who was ultimately diagnosed by laparoscopic liver biopsy. The patient was a 42-year-old ...

متن کامل

Duodenal switch has no detrimental effects on hepatic function and improves hepatic steatohepatitis after 6 months.

BACKGROUND Nonalcoholic steatohepatitis (NASH) is a common histological finding on liver biopsy in morbidly obese patients. The condition, although benign, can progress to cirrhosis and liver failure. We investigated the effect of the duodenal switch (DS) operation on hepatic function and architecture, specifically hepatic steatosis and NASH. METHODS Between November 1999 and June 2004, 697 D...

متن کامل

Multiplex transcriptional analysis of paraffin-embedded liver needle biopsy from patients with liver fibrosis

UNLABELLED BACKGROUND The possibility of extracting RNA and measuring RNA expression from paraffin sections can allow extensive investigations on stored paraffin samples obtained from diseased livers and could help with studies of the natural history of liver fibrosis and inflammation, and in particular, correlate basic mechanisms to clinical outcomes. RESULTS To address this issue, a pilo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013