Evaluation of the dose variation for prostate heavy charged particle therapy using four-dimensional computed tomography

نویسندگان

  • Motoki Kumagai
  • Tohru Okada
  • Shinichiro Mori
  • Susumu Kandatsu
  • Hiroshi Tsuji
چکیده

We quantified dose variation effects due to respiratory-induced intrafractional motion in conventional carbon-ion prostate treatment by using four-dimensional computed tomography (4DCT). 4DCT scans of 20 patients were acquired under free-breathing conditions using a 256 multi-slice CT scanner. The clinical target volume (CTV) was defined as the prostate and the seminal vesicle. Two types of planning target volumes (PTVs) were defined to minimize excessive dose to the rectum. The first PTV (= PTV1) was calculated by adding a 3D uniform margin to the CTV. The second PTV (= PTV2) was cut in a straight line from the top surface of the rectum from PTV1. Compensating boli were designed for the respective PTVs at the peak-exhalation phase, and carbon-ion dose distributions for a single respiratory cycle were calculated using these boli. Dose conformation to prostate, CTV, PTV1 and PTV2 were unchanged for all respiratory phases. The dose for >95% volume irradiation (D95) was 97.7% for prostate, 92.5% for CTV, 74.1% for PTV1 and 96.1% for PTV2 averaged over all patients. The rectum volume at inhalation phase receiving ≤50% of the prescribed dose was smaller than the planning dose due to the abdominal thickness variation. The target dose is not affected by intrafractional respiration in carbon-ion prostate treatment. Small dose variations, however, were observed due to respiratory-induced abdominal thickness variation; therefore the geometrical changes should be considered for prostate particle therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Analysis of Hip Joint Dose in Prostate Cancer Radiation Therapy: A Dosimetric Comparison of Treatment Plans

Background and purpose: Radiation therapy as a part of cancer treatment is used in almost 50-60% of involved cases. In prostate cancer radiation therapy, a large volume of pelvis is irradiated, so, it is necessary to preserve sensitive organs around the treatment area, especially rectum and bladder. In this study, some dosimetric parameters such as minimum dose (Dmin), maximum dose (Dmax), mean...

متن کامل

A Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter

Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....

متن کامل

The efficacy of conventional external beam, three-dimensional conformal, intensity-modulated, particle beam radiation, and brachytherapy for localized prostate cancer.

Technologic advances in radiation treatment planning and delivery have generated popular interest in the different radiation therapy techniques used in treating patients with localized prostate cancer. Throughout the past decade, high-energy (> 4 MV) linear accelerators have largely replaced Cobalt machines in external beam radiation therapy (EBRT) delivery. Conventional EBRT has been used to t...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013