Nasal continuous positive airway pressure: influence on digital volume pulse in obstructive sleep apnoea patients.
نویسندگان
چکیده
Obstructive sleep apnoea (OSA) is linked to increased cardiovascular risk. This risk can be reduced by nasal continuous positive airway pressure (nCPAP) treatment. As OSA is associated with an increase of several vasoconstrictive factors, we investigated whether nCPAP influences the digital volume pulse wave. We performed digital photoplethysmography during sleep at night in 94 consecutive patients who underwent polysomnography and 29 patients treated with nCPAP. Digital volume pulse waves were obtained independently of an investigator and were quantified using an algorithm for continuous automated analysis. In patients with OSA and an apnoea/hypopnoea index (AHI) of >10 events · h(-1), a significant vasoconstriction was observed during the night (p<0.0001 by Friedman's test). A significant positive correlation existed between vasoconstriction and AHI (Spearman correlation, r = 0.27; p<0.01; n = 94) and the arousal index (Spearman correlation, r = 0.21; p < 0.05; n = 94). After 6 months of nCPAP treatment, the AHI was significantly reduced from 27 ± 3 events · h(-1) to 4 ± 2 events · h(-1) (each n = 29; p<0.001) and vasoconstriction during the night was significantly reduced from 10 ± 3% to 3 ± 1% (p<0.01). We show changes in the reflective index during the night consistent with vasoconstriction in patients with OSA, which are significantly reduced after 6 months of nCPAP treatment.
منابع مشابه
Simultaneous sleep study and nasoendoscopic investigation in a patient with obstructive sleep apnoea syndrome refractory to continuous positive airway pressure: a case report
INTRODUCTION The standard treatment for obstructive sleep apnoea syndrome is nasal continuous positive airway pressure. In most cases the obstruction is located at the oropharyngeal level, and nasal continuous positive airway pressure is usually effective. In cases of non-response to nasal continuous positive airway pressure other treatments like mandibular advancement devices or upper airway s...
متن کاملSevere obstructive sleep apnoea treated with long term nasal continuous positive airway pressure.
Seven patients with the severe obstructive sleep apnoea syndrome were treated with nasal continuous positive airway pressure for from three to 22 months. This treatment reversed all symptoms due to the syndrome in every patient and continued to be used in five patients. One patient stopped treatment after eight months and subsequently remained incapacitated and another underwent tracheostomy at...
متن کاملNasal continuous positive airway pressure with supplemental oxygen in coexistent sleep apnoea-hypopnoea syndrome and severe chronic obstructive pulmonary disease.
The objective of our study was to assess the application of nasal continuous positive airway pressure (nCPAP) with supplemental oxygen for correction of upper airway obstructive episodes and hypoxaemia during sleep in stable patients with sleep apnoea-hypopnoea syndrome (SAHS) and severe chronic obstructive pulmonary disease (COPD). Ten male patients with symptomatic SAHS and severe COPD (force...
متن کاملCerebrospinal fluid leak associated with nasal continuous positive airway pressure treatment for obstructive sleep apnoea.
Clear rhinorrhoea is a common symptom in patients with obstructive sleep apnoea (OSA), which may worsen with nasal continuous positive airway pressure treatment (nCPAP). However, rhinorrhoea can also be the presenting symptom of cerebrospinal fluid (CSF) leak, which is due to a communication between the subarachnoid space and the nasal cavity or sinuses. We report another case of a patient with...
متن کاملResidual effect of nCPAP applied for part of the night in patients with obstructive sleep apnoea.
The aim of the present study was to assess whether nasal continuous positive airway pressure (nCPAP) treatment, applied for only a few hours at the beginning of the night, has any residual effect on sleep and breathing during the ensuing hours of unassisted sleep in patients with obstructive sleep apnoea syndrome (OSAS). In 27 patients with newly-diagnosed OSAS, effective nCPAP was applied duri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 39 5 شماره
صفحات -
تاریخ انتشار 2012