Use of Backboard and Deflation Improve Quality of Chest Compression When Cardiopulmonary Resuscitation Is Performed on a Typical Air Inflated Mattress Configuration
نویسندگان
چکیده
No study has examined the effectiveness of backboards and air deflation for achieving adequate chest compression (CC) depth on air mattresses with the typical configurations seen in intensive care units. To determine this efficacy, we measured mattress compression depth (MCD, mm) on these surfaces using dual accelerometers. Eight cardiopulmonary resuscitation providers performed CCs on manikins lying on 4 different surfaces using a visual feedback system. The surfaces were as follows: A, a bed frame; B, a deflated air mattress placed on top of a foam mattress laid on a bed frame; C, a typical air mattress configuration with an inflated air mattress placed on a foam mattress laid on a bed frame; and D, C with a backboard. Deflation of the air mattress decreased MCD significantly (B; 14.74 ± 1.36 vs C; 30.16 ± 3.96, P < 0.001). The use of a backboard also decreased MCD (C; 30.16 ± 3.96 vs D; 25.46 ± 2.89, P = 0.002). However, deflation of the air mattress decreased MCD more than use of a backboard (B; 14.74 ± 1.36 vs D; 25.46 ± 2.89, P = 0.002). The use of a both a backboard and a deflated air mattress in this configuration reduces MCD and thus helps achieve accurate CC depth during cardiopulmonary resuscitation.
منابع مشابه
Reducing the impact of intensive care unit mattress compressibility during CPR: a simulation-based study
Background The depth of chest compression (CC) during cardiac arrest is associated with patient survival and good neurological outcomes. Previous studies showed that mattress compression can alter the amount of CCs given with adequate depth. We aim to quantify the amount of mattress compressibility on two types of ICU mattresses and explore the effect of memory foam mattress use and a backboard...
متن کاملManual versus Mechanical Chest Compressions on Surfaces of Varying Softness with or without Backboards: A Randomized, Crossover Manikin Study.
BACKGROUND Chest compression quality is decisive for overall outcome after cardiac arrest. Chest compression depth may decrease when cardiopulmonary resuscitation (CPR) is performed on a mattress, and the use of a backboard does not necessarily improve compression depth. Mechanical chest compression devices may overcome this problem. OBJECTIVES We sought to investigate the effectiveness of ma...
متن کاملA Feasibility Study for Measuring Accurate Chest Compression Depth and Rate on Soft Surfaces Using Two Accelerometers and Spectral Analysis
Background. Cardiopulmonary resuscitation (CPR) feedback devices are being increasingly used. However, current accelerometer-based devices overestimate chest displacement when CPR is performed on soft surfaces, which may lead to insufficient compression depth. Aim. To assess the performance of a new algorithm for measuring compression depth and rate based on two accelerometers in a simulated re...
متن کاملPerformance of different support surfaces during experimental resuscitation (CPR)
The relationship between the efficacy of resuscitation and the mattresses and backboards used in acute care units, has been studied previously. However, few reports focus on the relative efficacy of resuscitation when using mattresses with different modes of function. This study examines the performance of different support surfaces during experimental cardiopulmonary resuscitation (CPR). The s...
متن کاملComparison of the Effects of Three Different Counting Methods on Cardiopulmonary Resuscitation Quality and Rescuer Fatigue
Background: Chest compression with adequate depth and number is one of the main indicators of high-quality cardiopulmonary resuscitation (CPR). Nevertheless, no proper counting technique is suggested to provide sufficient number of massages. Aim: To compare the effects of three techniques of chest compression counting on the quality of CPR and rescuer fatigue. Method: Inthis clinical trial, 30 ...
متن کامل