Automated detection of effective left-ventricular pacing: going beyond percentage pacing counters.

نویسندگان

  • Subham Ghosh
  • Robert W Stadler
  • Suneet Mittal
چکیده

AIMS Cardiac resynchronization therapy (CRT) devices report percentage pacing as a diagnostic but cannot determine the effectiveness of each paced beat in capturing left-ventricular (LV) myocardium. Reasons for ineffective LV pacing include improper timing (i.e. pseudofusion) or inadequate pacing output. Device-based determination of effective LV pacing may facilitate optimization of CRT response. METHODS AND RESULTS Effective capture at the LV cathode results in a negative deflection (QS or QS-r morphology) on a unipolar electrogram (EGM). Morphological features of LV cathode-RV coil EGMs were analysed to develop a device-based automatic algorithm, which classified each paced beat as effective or ineffective LV pacing. The algorithm was validated using acute data from 28 CRT-defibrillator patients. Effective LV pacing and pseudofusion was simulated by pacing at various AV delays. Loss of LV capture was simulated by RV-only pacing. The algorithm always classified LV or biventricular (BV) pacing with AV delays ≤60% of patient's intrinsic AV delay as effective pacing. As AV delays increased, the percentage of beats classified as effective LV pacing decreased. Algorithm results were compared against a classification truth based on correlation coefficients between paced QRS complexes and intrinsic rhythm QRS templates from three surface ECG leads. An average correlation >0.9 defined a classification truth of ineffective pacing. Compared against the classification truth, the algorithm correctly classified 98.2% (3240/3300) effective LV pacing beats, 75.8% (561/740) of pseudofusion beats, and 100% (540/540) of beats with loss of LV capture. CONCLUSION A device-based algorithm for beat-by-beat monitoring of effective LV pacing is feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The utility of 12-lead Holter monitoring in patients with permanent atrial fibrillation for the identification of nonresponders after cardiac resynchronization therapy.

OBJECTIVES This study sought to determine the incidence of ineffective capture using 12-lead Holter monitoring and to assess whether this affects response to cardiac resynchronization therapy (CRT). BACKGROUND Cardiac resynchronization therapy is used in patients with atrial fibrillation (AF), prolonged QRS duration, and heart failure in the setting of ventricular dysfunction. The percentage ...

متن کامل

Biventricular pacing in patients with bradycardia and normal ejection fraction.

BACKGROUND Observational studies suggest that conventional right ventricular apical pacing may have a deleterious effect on left ventricular function. In this study, we examined whether biventricular pacing is superior to right ventricular apical pacing in preventing deterioration of left ventricular systolic function and cardiac remodeling in patients with bradycardia and a normal ejection fra...

متن کامل

Cardiomyopathy induced by artificial cardiac pacing: myth or reality sustained by evidence?

Implantable cardiac pacing systems are a safe and effective treatment for symptomatic irreversible bradycardia. Under the proper indications, cardiac pacing might bring significant clinical benefit. Evidences from literature state that the action of the artificial pacing system, mainly when the ventricular lead is located at the apex of the right ventricle, produces negative effects to cardiac ...

متن کامل

Permanent Parahisian Pacing

Right Ventricular Apical permanent pacing could have negative hemodynamic effects. A physiologic pacing modality should preserve a correct atrio-ventricular and interventricular synchronization. This can be obtained through biventricular pacing, left ventricular pacing, or from alternative right ventricular pacing sites. Direct His Bundle Pacing (DHBP) was documented as reliable and effective f...

متن کامل

Role of atrial contraction and synchrony of ventricular contraction in the optimisation of ventriculoarterial coupling in humans.

OBJECTIVE To examine the effects of pacing modes on the interaction between the left ventricle and arterial system in humans. DESIGN The slope of the end systolic pressure-volume relation (end systolic elastance), effective arterial elastance, the ratio of effective arterial elastance to end systolic elastance, and mechanical energy efficiency were compared under different pacing modes (atria...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 17 10  شماره 

صفحات  -

تاریخ انتشار 2015