Minimal Medial-row Tie with Suture-bridge Technique for Medium to Large Rotator Cuff Tears
نویسندگان
چکیده
Background: The purpose of this study was to evaluate the postoperative magnetic resonance imaging (MRI) results of minimal-tying (one medial-row tie among 4 medial-row sutures) on the medial-row in double–row suture-bridge configuration (2×2 anchor with 4×4 suture stands). Methods: From 2011 March to 2012 July, 79 patients underwent arthroscopic rotator cuff repair using 2×2 anchor double-row configuration. The mean age was 61.3 years (range, 31–81 years). Two double-loaded suture anchors were used for medial-row. Four medialrow stitches were made with only one medial-row knot-tying (the most anterior suture). Lateral-row was secured using the conventional suture-bridge anchor technique; all 4 strands were used for each anchor. Repair integrity was evaluated with MRI at mean 6.2 months postoperatively. Retear and the pattern of retear, change of fatty infiltration, and muscle atrophy of supraspinatus were evaluated using preand postoperative MRI. Results: Repaired tendon integrity was 38 for type I, 30 for type II, 6 for type III, 4 for type IV, and 1 for type V, according to Sugaya classification. Considering type IV/V as retear, the rate was 6.3% (5 out of 79 patients). Medial cuff failure was observed in 4 patients. Fatty atrophy of supraspinatus was significantly improved postoperatively according to Goutallier grading (p=0.01). The level of muscle atrophy of supraspinatus was not changed significantly after surgery. Conclusions: Minimal tying technique with suture configuration of four-by-four strand double-row suture-bridge yielded a lower retear rate (6.3%) in medium to large rotator cuff tears. (Clin Shoulder Elbow 2015;18(4):197-205)
منابع مشابه
Arthroscopic Rotator Cuff Repair: A Biomechanical Comparison of Single Row and Suture-Bridge Tendon Repair Constructs
INTRODUCTION: Rotator cuff tears are a very common source of pain and loss of function of the shoulder. As arthroscopic instrumentation and repair techniques have evolved, many studies have demonstrated success in repairing rotator cuff tears using these arthroscopic techniques alone compared with an open repair method. Despite these successful clinical outcomes, both open and arthroscopic rota...
متن کاملBiomechanical Performance of Medial Row Suture Placement Relative to the Musculotendinous Junction in Transosseous Equivalent Suture Bridge Double-Row Rotator Cuff Repair.
PURPOSE To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. METHODS A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row...
متن کاملPreliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix
Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...
متن کاملSoft tissue tenodesis of the long head of the biceps tendon associated to the Roman Bridge repair
BACKGROUND Rotator cuff tears are frequently associated with pathologies of the long head of the biceps tendon (LHBT). Tenotomy and tenodesis of the LHBT are commonly used to manage disorders of the LHBT. METHODS We present an arthroscopic soft tissue LHBT tenodesis associated with a Roman Bridge (double pulley - suture bridges) repair RESULTS Two medial row 5.5-mm Bio-Corkscrew suture anch...
متن کاملComparison of the Clinical and Radiological Oucomes of Conventional Double row and Double row Suture Bridge Repairs in Rotator Cuff Tears
This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...
متن کامل