Impact of Age on Stent Strut Coverage and Neointimal Remodeling as Assessed by Optical Coherence Tomography
نویسندگان
چکیده
While older age associates with adverse percutaneous coronary intervention (PCI) outcomes, detailed information relating age to stent strut coverage and neointimal characteristics is lacking. One hundred nineteen patients with 123 sirolimus-eluting stents (SESs) were divided into 3 groups: group A (≤55 years), group B (56-65 years), and group C (>65 years). At 6 and 12 months of follow-up, optical coherence tomography was performed to assess strut coverage and neointimal remodeling. At 6 months, the proportion of uncovered struts increased with age: 6.1% in group A versus 7.3% in group B versus 11.7% in group C (P < 0.001) while the proportion of embedded struts decreased: 72.1% versus 57.0% vs. 55.0%, respectively (P < 0.001). Mean neointimal thicknesses were 90 μm versus 60 μm versus 60 μm, respectively (P < 0.001), and neointimal areas were 0.82 mm2 versus 0.52 mm2 versus 0.57 mm2 (P < 0.001). At 12 months, the proportion of uncovered struts increased with age (3.9% vs. 3.3% vs. 4.9 %; P < 0.001), while mean neointimal thicknesses were 100 versus 70 versus 80 μm (P < 0.001) and neointimal areas were 0.87 versus 0.60 versus 0.67 mm2 (P < 0.001). Patients ≤55 years receiving SES showed highest strut coverage and neointimal repair rate compared with the other 2 groups. A "catch-up phenomenon" appeared to occur in the oldest patients, as in the first 6 months the neointima showed lowest endothelial cell coverage and lowest neointimal proliferation rate, whereas from 6 to 12 months, the highest neointimal proliferation rate was seen in the oldest patients.
منابع مشابه
The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.
OBJECTIVES This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. BACKGROUND Tracking the fate of interested regions of struts at different time points has not been investigated. METHODS Post-intervention and 6-month follow-up optical coherence tomographic evaluations were per...
متن کاملIncomplete stent apposition causes high shear flow disturbances and delay in neointimal coverage as a function of strut to wall detachment distance: implications for the management of incomplete stent apposition.
BACKGROUND Lack of re-endothelialization and neointimal coverage on stent struts has been put forward as the main underlying mechanism leading to late stent thrombosis. Incomplete stent apposition (ISA) has been observed frequently in patients with very late stent thrombosis after drug eluting stent implantation, suggesting a role of ISA in the pathogenesis of this adverse event. The aim of thi...
متن کاملOptical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.
OBJECTIVES We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. BACKGROUND Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. METHODS Seventy-...
متن کاملStent Evaluation with Optical Coherence Tomography
Optical coherence tomography (OCT) has been recently applied to investigate coronary artery disease in interventional cardiology. Compared to intravascular ultrasound, OCT is able to visualize various vascular structures more clearly with higher resolution. Several validation studies have shown that OCT is more accurate in evaluating neointimal tissue after coronary stent implantation than intr...
متن کاملHistological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.
Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological me...
متن کامل