Transcatheter closure of the patent ductus arteriosus using an Amplatzer duct occluder in adults.

نویسندگان

  • C H Lee
  • Y L Leung
  • W H Chow
چکیده

Patent ductus arteriosus (PDA) is a congenital heart disease that frequently escapes detection until the patient reaches adulthood. Percutaneous closure of the PDA has been established as a safe alternative to surgery, the Amplatzer duct occluder (ADO) is a new device that has been recently reported in paediatric patients. Our initial experience with an of ADO in an adult population appears to be encouraging and as good as in paediatric patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder.

The Amplatzer duct occluder (ADO) (AGA Medical Corp., Golden Valley, MN) is designed to meet criteria for an optimal transcatheter technique for closure of a patent ductus arteriosus. It was developed as an alternative to surgical closure and other interventional techniques. It is not technically complex, allows controlled deployment, is retrievable and repositionable, and has a low risk of emb...

متن کامل

Percutaneous Forceps Retrieval of an Embolized Amplatzer Duct Occluder

Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips...

متن کامل

Transcatheter closure of patent arterial duct with amplatzer duct occluder II additional sizes in children.

Amplatzer duct occluder II additional sizes is a new generation of device for arterial duct closure, appropriate for infants and older children. We report the successful transcatheter closure of the arterial duct in an infant and two older children with the above-mentioned device.

متن کامل

Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder.

AIM To evaluate whether transcatheter closure with the Amplatzer duct occluder offers an alternative to surgical treatment in infants with a persistent ductus arteriosus. METHODS 12 patients under 1 year of age (age 1-11 months, body weight 2.6-8.7 kg) with clinical and echocardiographic findings of a significant duct were considered for transcatheter closure with the Amplatzer occluder. The ...

متن کامل

Successful transcatheter closure of a residual patent ductus arteriosus with complex anatomy after surgical ligation using an amplatzer ductal occluder guided by live three-dimensional transesophageal echocardiography.

Residual patent ductus arteriosus (PDA) after surgical ligation is not common, but the anatomy of the residual duct may be distorted by the surgical ligation resulting in a difficult transcatheter closure. Such distorted anatomy of the duct may not be demonstrated by the two-dimensional transesophageal echocardiography (2D TEE). Fortunately, live 3D TEE provided the precise anatomy of the elong...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese heart journal

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 2001