Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
نویسندگان
چکیده
BACKGROUND Bile esculin azide with vancomycin (BEAV) medium is a sensitive, but slightly less specific method for vancomycin-resistant enterococci (VRE) screening. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a rapid method for identification of clinical pathogens. This study aimed to assess the performance of a novel combination screening test for VRE, using BEAV broth combined with MALDI-TOF MS. MATERIALS AND METHODS Clinical specimens were collected from patients at risk of VRE carriage, and tested by the novel combination method, using selective BEAV broth culture method followed by MALDI-TOF MS identification (SBEAVM). The reference method used for comparison was the ChromID VRE agar method. RESULTS A total of 135 specimens were collected from 78 patients, and 63 specimens tested positive for VRE positive using the ChromID VRE method (positive rate 46.7%). The sensitivity, specificity, positive predictive value, and negative predictive value of SBEAVM method after an incubation period of 28 hours were 93.7%, 90.3%, 89.4%, and 94.2%, respectively. The SBEAVM method when compared to the ChromID VRE method had a shorter turnaround time (29 vs. 48-72 hours) and lower laboratory cost ($2.11 vs. $3.23 per test). CONCLUSIONS This study demonstrates that SBEAVM is a rapid, inexpensive, and accurate method for use in VRE screening.
منابع مشابه
Use of matrix-assisted laser desorption ionization-time of flight mass spectrometry to identify vancomycin-resistant enterococci and investigate the epidemiology of an outbreak.
The control of vancomycin-resistant enterococci (VRE) has become an increasing burden on health care resources since their discovery over 20 years ago. Current techniques employed for their detection include time-consuming and laborious phenotypic methods or molecular methods requiring costly equipment and consumables and highly trained staff. An accurate, rapid diagnostic test has the ability ...
متن کاملA Decade of Development of Chromogenic Culture Media for Clinical Microbiology in an Era of Molecular Diagnostics.
In the last 25 years, chromogenic culture media have found widespread application in diagnostic clinical microbiology. In the last decade, the range of media available to clinical laboratories has expanded greatly, allowing specific detection of additional pathogens, including Pseudomonas aeruginosa, group B streptococci, Clostridium difficile, Campylobacter spp., and Yersinia enterocolitica. N...
متن کاملVerification of a Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Method for Diagnostic Identification of High-Consequence Bacterial Pathogens.
We examined the utility of a single matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry method for the identification of security-sensitive biological agents (risk group 3 bacterial pathogens). The goal was 2-fold: to verify a method for inclusion into our scope of accreditation, and to assess the biological safety of extractions. We developed our sample flo...
متن کاملA novel bacteriocin from Enterococcus faecalis 478 exhibits a potent activity against vancomycin-resistant enterococci
The emergence of multidrug-resistant enterococci (MDRE) and particularly vancomycin-resistant enterococci (VRE) is considered a serious health problem worldwide, causing the need for new antimicrobials. The aim of this study was to discover and characterize bacteriocin against clinical isolates of MDRE and VRE. Over 10,000 bacterial isolates from water, environment and clinical samples were scr...
متن کاملFunctionalized nanoparticles and nanostructured surfaces for surface-assisted laser desorption/ionization mass spectrometry.
Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF-MS) using nanoparticles (NPs) and nanostructured surfaces as the LDI-assisting nanomaterials is a soft ionization technique that features minimal fragmentation of analytes. As compared to traditional matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) using organic ma...
متن کامل