The effect of mechanical and chemical polishing techniques on the surface roughness of heat-polymerized and visible light-polymerized acrylic denture base resins.
نویسنده
چکیده
OBJECTIVE The purpose of this study was to compare the effects of mechanical polishing (MP) and chemical polishing (CP) on the average surface roughness (Ra) of heat-cured (HC) and light-cured (LC) denture base acrylic resins. METHODS A total of 120 specimens (30 × 15 × 3 mm) were prepared from one HC and one LC acrylic resin. To remove nodules and gross surface irregularities, all specimens were finished with a lathe-mounted small acrylic bur and 360-grit sandpaper. Ten finished specimens of each acrylic resin were randomly assigned to each of six polishing techniques: Resilit High-luster Polishing Liquid (RHPL), Universal Polishing Paste, Abraso-star K50, pumice, Jet Seal Liquid, or Acrypoint. MP was performed with an automatic polishing machine for 2 min, under 50 rpm and 500 g of load. CP was performed by immersing the HC and LC specimens in preheated methyl methacrylate at 75 ± 1 °C for 10 s. The surface roughness of the acrylic resin specimens was measured with a contact profilometer. The Ra values were analyzed by two-way analysis of variance, post hoc Scheffe's test, and paired t-test (p ⩽ 0.05). Polished and tested acrylic resin surfaces were evaluated by scanning electron microscopy. RESULTS MP was more effective than CP. The smoothest surface was obtained with the use of the RHPL on the LC (0.05 ± 0.01 μm) or HC (0.07 ± 0.01 μm) acrylic resin. Two-way ANOVA showed a statistically significant difference between MP and CP. CONCLUSIONS MP produced the smoothest surface of denture base acrylic resin. The mean surface roughness values after MP and CP were not influenced by the type of acrylic resin.
منابع مشابه
بررسی تأثیر ضدعفونی کننده های شیمیایی بر خشونت سطحی آکریل بیس دنچر گرماپخت
Introduction & Objective: Chemical disinfectants should have minimum side effects on the denture base surface so they can reduce the amount of plaque accumulation. This study evaluates the effect of chemical disinfectants (glutaraldehyde 2% and sodium hypochlorite 1%, 2.5% and 5.25%) on surface roughness of heat cure acrylic denture. Materials & Methods: Fifty specimens were fabricated with...
متن کاملThe influence of polishing techniques on pre-polymerized CAD\CAM acrylic resin denture bases
Background Lately, computer-aided design and computer-aided manufacturing (CAD/CAM) has broadly been successfully employed in dentistry. The CAD/CAM systems have recently become commercially available for fabrication of complete dentures, and are considered as an alternative technique to conventionally processed acrylic resin bases. However, they have not yet been fully investigated. Objectiv...
متن کاملInfluence of a Cobalt-chromium Metal Framework on Surface Roughness and Knoop Hardness of Visible Light-polymerized Acrylic Resins
Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the ro...
متن کاملDynamic mechanical properties of hard, direct denture reline resins.
STATEMENT OF PROBLEM Dynamic mechanical properties of hard, direct reline resins are important factors in the clinical success of dentures. However, little information is available on the nature of these properties. PURPOSE This study evaluated the dynamic mechanical properties of a variety of hard, direct reline resins: (1) visible light-polymerized, powder-liquid type, (2) visible light-pol...
متن کاملComparative Evaluation of the Flexural Strength of Heat Polymerized Acrylic Resin with the Addition of 8% and 13% Aluminum Oxide Powder: An In-vitro Study
Introduction: Acrylic resins have been used successfully as denture bases. However, acrylic resin denture base materials are brittle and have poor strength and thermal conductivity. Therefore, it is essential to improve the flexural strength of heat polymerized acrylic resin. The present study aimed to evaluate and compare the flexural strength of heated polymerized acrylic res...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Saudi dental journal
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2014