A digital calliper for training and study purposes.

نویسندگان

  • Maria T Restivo
  • Teresa F Amaral
  • Maria F Chouzal
  • Celina P Leão
  • Rita S Guerra
  • Elisa Marques
  • Joaquim Mendes
  • Manuel Quintas
  • Jorge Mota
چکیده

A quick and valid method for evaluating percentage body fat is based on the use of skinfold callipers. However, limitations associated to their use and characteristics led the authors to improve a traditional calliper (Harpenden) and to integrate it with a software application. Such a measuring system, LipoTool, is meant to have better accuracy and reliability, including data processing and digital recording at a very low cost. At first, a sample of 49 older adults was used to evaluate the performance of LipoTool by comparing its results to those obtained with the traditional Harpenden calliper. A strong positive association in %BF was achieved. This digital sensing system was later improved by incorporating wireless communication between the calliper and the software application, adding other functionalities. The software application works in any computer and is flexible to incorporate new coming models, linear regressions or new algorithms. This new system was validated against the standard Dual-Energy X-Ray Absorptiometry system, using a sample of 40 adults with positive results. This solution is a valid and reliable alternative to traditional reference callipers, simplifying the percentage of body fat evaluation and providing a more effective use in daily practice with less expenditure of time and resources. Its implemented guided procedure turns it into a precious training tool based on a non-invasive, portable device, and not requiring special individual preparation. Ongoing activities are focused on the design of a new mechanical structure, with novel functionalities and for exploring other studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of foot arch measurement reliability using both digital photography and calliper methods

BACKGROUND Both calliper devices and digital photographic methods have been used to quantify foot arch height parameters. The purpose of this study was to compare the reliability of both a calliper device and digital photographic method in determining the arch height index (AHI). METHODS Twenty subjects underwent measurements of AHI on two separate days. On each day, AHI measurements during b...

متن کامل

Accuracy of a digital skinfold system for measuring skinfold thickness and estimating body fat.

The use of skinfold thickness measurements to evaluate the distribution of subcutaneous adipose tissue and to predict body fat has recognised advantages. However, the different types of skinfold calliper available present limitations that make them unattractive and perhaps less used in daily practice. The purpose of the present study was to evaluate the accuracy and functionality of a new digit...

متن کامل

Digital Competencies Of Teachers In The Transformation Of The Educational Environment

The purpose of this study is to determine the main directions of development of digital competencies of teachers to ensure a quality educational process in the transformation of the educational environment. The relevance of this study is due to the need to determine the main directions of development of the education system for adaptation in the context of digitalization of society. It is estab...

متن کامل

Translation Evaluation in Educational Settings for Training Purposes

The following article describes different methods and techniques used in educational settings for translation evaluation. Translation evaluation is the placing of value on a translation i.e. awarding a mark, even if only a binary pass/fail one. In the present study, different features of the texts chosen for evaluation were firstly considered and then scoring the t...

متن کامل

A Randomized Controlled Trial of the Effects of Supervised Aerobic Training Program on Anthropometry, Lipid Profile and Body Composition in Obese Adult Leukemic Patients

Background: The purpose of this randomized study was to examine the effects of a supervised aerobic training program on anthropometry, lipid profile and body composition of obese adult leukemia survivors. Methods: Fifty-four obese adult leukemia survivors were allocated randomly into two groups of equal number. The intervention group underwent a supervised aerobic training program for 30-40 mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Asia Pacific journal of clinical nutrition

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2012