A pilot study of a low-tilt biphasic waveform for transvenous cardioversion of atrial fibrillation: improved efficacy compared with conventional capacitor-based waveforms in patients.
نویسندگان
چکیده
BACKGROUND The optimal waveform tilt for defibrillation is not known. Most modern defibrillators used for the cardioversion of atrial fibrillation (AF) employ high-tilt, capacitor-based biphasic waveforms. METHODS We have developed a low-tilt biphasic waveform for defibrillation. This low-tilt waveform was compared with a conventional waveform of equivalent duration and voltage in patients with AF. Patients with persistent AF or AF induced during a routine electrophysiology study (EPS) were randomized to receive either the low-tilt waveform or a conventional waveform. Defibrillation electrodes were positioned in the right atrial appendage and distal coronary sinus. Phase 1 peak voltage was increased in a stepwise progression from 50 V to 300V. Shock success was defined as return of sinus rhythm for >/=30 seconds. RESULTS The low-tilt waveform produced successful termination of persistent AF at a mean voltage of 223 V (8.2 J) versus 270 V (6.7 J) with the conventional waveform (P = 0.002 for voltage, P = ns for energy). In patients with induced AF the mean voltage for the low-tilt waveform was 91V (1.6 J) and for the conventional waveform was 158 V (2.0 J) (P = 0.005 for voltage, P = ns for energy). The waveform was much more successful at very low voltages (less than or equal to 100 V) compared with the conventional waveform (Novel: 82% vs Conventional 22%, P = 0.008). CONCLUSION The low-tilt biphasic waveform was more successful for the internal cardioversion of both persistent and induced AF in patients (in terms of leading edge voltage).
منابع مشابه
Junior Members Forum
The use of a low tilt biphasic waveform lowers the defibrillation threshold for the internal cardioversion of atrial fibrillation Purpose: Conventional defibrillators used for the internal cardioversion of atrial fibrillation (AF) employ high tilt waveforms generated by a capacitor based discharge. We have developed a biphasic waveform with low tilt. This was compared with a conventional wavefo...
متن کاملComparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.
BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. Th...
متن کاملInternal cardioversion of atrial fibrillation in sheep.
BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...
متن کاملNovel passive implantable atrial defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation.
BACKGROUND Conventional methods for cardioversion of atrial fibrillation (AF) to sinus rhythm have numerous difficulties. A novel method for cardioversion using the passive implantable atrial defibrillator (PIAD) was tested in acute animal models. This device does not have a battery or a capacitor to store energy and is activated by transferring RF energy across the skin from an external transm...
متن کاملInternal Cardioversion of Atrial Fibrillation in Sheep Randolph
Background. The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. Methods and Results. Sustained atrial fibrillation couldbe induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each par...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 31 8 شماره
صفحات -
تاریخ انتشار 2008