Ultra-Fast Determination of Scopolamine, Orphenadrine, Mepyramine, Caffeine, Dipyrone, and Ascorbic Acid by Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection

نویسندگان

  • Mariana C. Marra
  • Polyana L. Silva
  • Rodrigo A. A. Muñoz
  • Eduardo M. Richter
چکیده

Neste trabalho apresentamos um método de eletroforese capilar simples e de baixo custo para determinação ultra-rápida de princípios ativos presentes em três formulações farmacêuticas diferentes: (i) escopolamina (SCO) e dipirona (DIP); (ii) orfenadrina (ORP), cafeína (CAF) e DIP; (iii) mepiramina (MEP), CAF, DIP e ácido ascórbico (AA). O método proposto é baseado em eletroforese capilar com detecção condutométrica sem contato (CE-CD). As amostras podem ser analisadas em uma única corrida (≤ 1 minuto) usando 10 mmol L de 3,4-dimetoxicinamato e 12 mmol L de trietanolamina como eletrólito de corrida (pH = 8,5). Uma resposta linear (r ≥ 0,993) foi obtida entre 0,10 e 0,50 mmol L para SCO, entre 0,25 e 1,25 mmol L para ORP e MEP, entre 0,50 e 2,50 mmol L para DIP e CAF e entre 1,00 e 3,00 mmol L para AA. Os limites de detecção foram 0,02, 0,05, 0,03, 0,04, 0,02 e 0,06 mmol L para SCO, DIP, ORP, CAF, MEP e AA, respectivamente. Além disto, o método proposto também forneceu resultados adequados nos estudos de precisão intra (≤ 4%) e inter (≤ 14%) dias, assim como resultados satisfatórios nos estudo de adição e recuperação (entre 92% e 103%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of haloacetic acids in water using solid-phase extraction/microchip capillary electrophoresis with capacitively coupled contactless conductivity detection.

Haloacetic acids (HAAs) were determined by a fast and simple analysis method based on microchip electrophoresis and capacitively coupled contactless conductivity detection (C(4)D). Two chlorinated acetic acids, dichloroacetic acid (DCAA) and TCA were detected in swimming pool water. Different BGEs were tested, and sodium carbonate was selected as BGE for the separation and detection in the repo...

متن کامل

Comparison of Potassium and Sodium Content in Diet and Non-Diet Soft Drinks by Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection

Capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) was used for determination of sodium and potassium concentrations in diet and non-diet soft drinks. Higher sodium concentrations were found in the diet samples due to the utilization of sodium salts of cyclamate and saccharine as sweeteners. The CE-C4D method can be used by food industries and heal...

متن کامل

Accurate non-invasive determination of pKa of surface functionalised ion exchange monoliths using capacitively coupled contactless conductivity detection.

The use of on-column capacitively coupled contactless conductivity detection for the accurate non-invasive visualisation of the pH dependence of covalently bound boronic acid groups within a monolithic polymeric capillary column is demonstrated.

متن کامل

Contactless Conductivity Detection in Ceramic Technology for On-Chip Electrophoresis

A capacitively coupled contactless conductivity detector produced in Low Temperature Co-fired Ceramic (LTCC) technology for microchip capillary electrophoresis (CE) is reported in this work. Electrodes located outside the measurement channel are used to sense impedance variations caused by conductive ions. The application of LTCC in combination with contactless conductivity detection is very pr...

متن کامل

Study of the determination of inorganic arsenic species by CE with capacitively coupled contactless conductivity detection.

The determination of arsenic(III) and arsenic(V), as inorganic arsenite and arsenate, was investigated by CE with capacitively coupled contactless conductivity detection (CE-C(4)D). It was found necessary to determine the two inorganic arsenic species separately employing two different electrolyte systems. Electrolyte solutions consisting of 50 mM CAPS/2 mM L-arginine (Arg) (pH 9.0) and of 45 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014