Correlation of Serial Scleral and Corneal Pneumatonometry.
نویسندگان
چکیده
PURPOSE To evaluate the usefulness of scleral pneumatonometry as an alternative for corneal measurements of intraocular pressure (IOP) over a broad range of IOPs. DESIGN Prospective, observational cohort study. PARTICIPANTS The study was conducted in the University of California, San Francisco, Retina Clinic between August and November 2013 in 33 adult patients (age range, 34-94 years; mean ± standard deviation, 74.1±13.4 years) receiving anti-vascular endothelial growth factor intravitreal injections, which transiently increase IOP. METHODS Corneal pachymetry and serial corneal and temporal scleral pneumatonometry (baseline, immediately after, and 10, 20, and 30 minutes after injection) were collected. One-time baseline corneal and scleral pneumatonometry readings were obtained in the noninjected eye. MAIN OUTCOME MEASURES Correlation analysis and a Bland-Altman plot were used to evaluate reliability and agreement between scleral and corneal measurements of IOP. A linear mixed model was used to determine the relationship between measurements and to perform covariate analyses. RESULTS Scleral and corneal pneumatonometry showed nearly 1:1 linear correlation, although scleral pneumatonometry was biased toward higher values (r = 0.94; P < 0.001). Scleral pneumatonometry averaged 9.0 mmHg higher than corneal pneumatonometry (95% limits of agreement, -1.5 to 19.5 mmHg). A linear mixed model resulted in the following equation: corneal IOP = 1.04 × scleral IOP - 10.37. Age, central corneal thickness, laterality, and glaucoma and lens status did not impact this relationship. The difference between corneal and scleral pneumotonometry was correlated between the two eyes of individual patients (r = 0.75; P < 0.001). CONCLUSIONS Differences between serial scleral measurements reflect differences between serial corneal measurements. Scleral pneumatonometry should be considered as an alternative to corneal pneumatonometry for following patients in whom corneal measurements are unreliable or unobtainable.
منابع مشابه
FOLLOW UP OF ONE HUNDRED CORNEAL AND SCLERAL RUPTURES DURING 1988-1990
In a retrospective study, one hundred corneosclerallaceration (CSL) cases were managed at Zahedan Ophthalmic Center from 1988-1990. Our findings showed that CSL is more commonly seen in young and male patients. Seasonal variation in CSL frequency with higher prevalence in the fust half of the years was evident. Also it was found that cataract was more common in corneal lacerations while hyp...
متن کاملبررسی تغییرات توپوگرافیک قرنیه بعد از اعمال جراحی اسکرال با کلینگ و ویترکتومی
To investigale the topographic changes in the cornea after scleral buckling and vitrectommy. A prospective study was conducted. Thses changes were analyzed based on the type of surgical procedures performed. Design of this study was observational prospective case series. 49 eyes from 48 patients were stratified into four groups based on the type of surgical procedures performed. 10 un...
متن کاملPilot Study for OCT Guided Design and Fit of a Prosthetic Device for Treatment of Corneal Disease
Purpose. To assess optical coherence tomography (OCT) for guiding design and fit of a prosthetic device for corneal disease. Methods. A prototype time domain OCT scanner was used to image the anterior segment of patients fitted with large diameter (18.5-20 mm) prosthetic devices for corneal disease. OCT images were processed and analyzed to characterize corneal diameter, corneal sagittal height...
متن کاملبررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه
ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...
متن کاملنتایج درازمدت نصب اسکلرال لنزهای داخل چشمی جابجا شده به روش خارج کردن هاپتیک از برش کوچک قرنیه
Background & Aim: Several methods have been reported for refixation of dislocated intraocular lenses (IOLs). However, these methods are associated with some disadvantages including vitreous prolaps, vitreous traction, ocular collapse, intraocular hemorrhage, high astigmatism, and the need for complex intraocular maneuvers. The aim of this study was to evaluate the results of transscleral fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 122 9 شماره
صفحات -
تاریخ انتشار 2015