Improved visualization of breast tissue on a dedicated breast PET system through ergonomic redesign of the imaging table
نویسندگان
چکیده
BACKGROUND Breast lesions closer than 2 cm to the chest wall are difficult to position in the field of view of dedicated breast PET (db-PET) systems. This inability to detect such lesions is a significant limitation of these systems. The primary objective of this study was to determine if modifications to the design of the imaging table and detector used for a db-PET system would enable improved visualization of breast tissue close to the chest wall. All studies were performed on a commercially available db-PET system (Mammi-PET). A central square section of the imaging table, containing the standard 180-mm circular aperture, was modified such that it could be removed and replaced by thinner sections with a larger aperture. Additional changes were made to the cover plate of the detector array and the patient mattress. A total of 60 patients were studied. After administration of F-18 FDG, 30 patients were imaged with a 220-mm-diameter aperture and the standard aperture, and 30 patients with a 200-mm aperture and the standard aperture. On all scans, the length of breast tissue in the field of view was measured as the greatest extent of tissue from the nipple back to the posterior edge of the breast. Image quality and patient comfort were recorded. RESULTS Averaged over both breasts, relative to the standard aperture, the increase in breast length was 12.5 + 7.7 mm with the 220-mm aperture, and 12.3 + 6.5 mm with the 200-mm aperture (p < 0.05 for both apertures). In ~ 5% of cases, the larger apertures resulted in some degradation in image quality due to closer proximity to cardiac/hepatic activity. In 10-20% of cases, movement of the breast tissue was observed as the detector ring was moved to scan the anterior region of the breast. The patient survey indicated no significant difference in the comfort level between the standard aperture and either of the prototype apertures. CONCLUSIONS Modifications to the image table and system resulted in a significant gain in the volume of breast tissue that could be imaged on the db-PET system and should allow better visualization of lesions close to the chest wall.
منابع مشابه
Validation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملTime frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information
Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...
متن کاملMolecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis
Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue. Methods:PubMed, Scopus and EMBASE were searched for st...
متن کاملBreast cancer imaging: a new role of Tc-99m sestamibi prone scintimammography for diagnosisof breast cancer
Mammography remians the procedure of choice in screening asymptomatic women for breast cancer. However, in patients with symptoms, other types of imaging play an important role in the detection of malignancies. The high cost and lack of availability of PET and MRI largely precludes the use in this patient population. TI-201 is nbt the imaging agent of choice because of its wash-out and redistri...
متن کاملBreast Radiation Protection in Coronary Angiography
Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...
متن کامل