The reproducibility and absolute values of echocardiographic measurements of left ventricular size and function in children are algorithm dependent.
نویسندگان
چکیده
BACKGROUND Several quantification algorithms for measuring left ventricular (LV) size and function are used in clinical and research settings. The aims of this study were to investigate the effects of measurement algorithm and beat averaging on the reproducibility of measurements of the left ventricle and to assess the magnitude of agreement among the algorithms in children with dilated cardiomyopathy. METHODS Echocardiograms were obtained in 169 children from eight clinical centers. Inter- and intrareader reproducibility was assessed on measurements of LV volumes using the biplane Simpson, modified Simpson, and 5/6 × area × length (5/6AL) algorithms. Percentage error was calculated as inter- or intrareader difference/mean × 100. Single-beat measurements and the three-beat average (3BA) were compared. Intraclass correlation coefficients were calculated to assess agreement. RESULTS Single-beat interreader reproducibility was lowest (percentage error was highest) using biplane Simpson; 5/6AL and modified Simpson were similar but significantly better than biplane Simpson (P < .05). Single-beat intrareader reproducibility was highest using 5/6AL (P < .05). The 3BA improved reproducibility for almost all measures (P < .05). Reproducibility in both single-beat and 3BA values fell with greater LV dilation and systolic dysfunction (P < .05). Intraclass correlation coefficients were >0.95 across measures, although absolute volume and mass values were systematically lower for biplane Simpson compared with modified Simpson and 5/6AL. CONCLUSIONS The reproducibility of LV size and functional measurements in children with dilated cardiomyopathy is highest using the 5/6AL algorithm and can be further improved by using the 3BA. However, values derived from different algorithms are not interchangeable.
منابع مشابه
Echocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation
Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملMeasurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملNormal Value of Left Ventricular End-Systolic Elastance in Infants and Children
Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance. Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...
متن کاملNormal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2015