Assessing the effect of electron density in photon dose calculations.

نویسندگان

  • J Seco
  • P M Evans
چکیده

Photon dose calculation algorithms (such as the pencil beam and collapsed cone, CC) model the attenuation of a primary photon beam in media other than water, by using pathlength scaling based on the relative mass density of the media to water. In this study, we assess if differences in the electron density between the water and media, with different atomic composition, can influence the accuracy of conventional photon dose calculations algorithms. A comparison is performed between an electron-density scaling method and the standard mass-density scaling method for (i) tissues present in the human body (such as bone, muscle, etc.), and for (ii) water-equivalent plastics, used in radiotherapy dosimetry and quality assurance. We demonstrate that the important material property that should be taken into account by photon dose algorithms is the electron density, and not the mass density. The mass-density scaling method is shown to overestimate, relative to electrondensity predictions, the primary photon fluence for tissues in the human body and water-equivalent plastics, where 6%-7% and 10% differences were observed respectively for bone and air. However, in the case of patients, differences are expected to be smaller due to the large complexity of a treatment plan and of the patient anatomy and atomic composition and of the smaller thickness of bone/air that incident photon beams of a treatment plan may have to traverse. Differences have also been observed for conventional dose algorithms, such as CC, where an overestimate of the lung dose occurs, when irradiating lung tumors. The incorrect lung dose can be attributed to the.incorrect modeling of the photon beam attenuation through the rib cage (thickness of 2-3 cm in bone upstream of the lung tumor) and through the lung and the oversimplified modeling of electron transport in convolution algorithms. In the present study, the overestimation of the primary photon fluence, using the mass-density scaling method, was shown to be a consequence of the differences in the hydrogen content between the various media studied and water. On the other hand, the electron-density scaling method was shown to predict primary photon fluence in media other than water to within 1%-2% for all the materials studied and for energies up to 5 MeV. For energies above 5 MeV, the accuracy of the electron-density scaling method was shown to depend on the photon energy, where for materials with a high content of calcium (such as bone, cortical bone) or for primary photon energies above 10 MeV, the pair-production process could no longer be neglected. The electron-density scaling method was extended to account for pair-production attenuation of the primary photons. Therefore the scaling of the dose distributions in media other than water became dependent on the photon energy. The extended electron-scaling method was shown to estimate the photon range to within 1% for all materials studied and for energies from 100 keV to 20 MeV, allowing it to be used to scale dose distributions to media other than water and generated by clinical radiotherapy photon beams with accelerator energies from 4 to 20 MV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Iridium_192 radioisotope dosimeter calculations for vascular Brachiotherapy

Introduction: One of the most effective means for treatment of coronary arteries cramp (CHD) is coronary intravascular Brachiotherapy. In this study, with use of MCNP code, in order to invastigating the score of ditribution of absorbed dose, drope in dose, and simulation mean, radiation doses around iridium_192 radioactive has been done.   Materials and Methods:</str...

متن کامل

بررسی کاهش مقدار عدم قطعیت محاسبات مونت‌کارلو دوز در شبیه‌سازی شتاب‌دهنده خطی بالینی Oncor®بااستفاده از تکنیک کاهش واریانس DBS در کدمونت‌کارلو BEAMnrc

Purpose: To study the benefits of Directional Bremsstrahlung Splitting (DBS) dose variance reduction technique in BEAMnrc Monte Carlo (MC) code for Oncor&reg; linac at 6MV and 18MV energies. Materials and Method: A MC model of Oncor&reg; linac was built using BEAMnrc MC Code and verified by the measured data for 6MV and 18MV energies of various field sizes. Then Oncor&reg; machine was modele...

متن کامل

Discrepancies in dose distributions due to age- dependent bone electron density in pediatric MRI-only treatment planning: A Monte Carlo study

Introduction: MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone den...

متن کامل

Fabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies

Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...

متن کامل

The effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study

Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 2006