Posterior Cortical Axis: A New Landmark to Control Femoral Component Rotation in Total Knee Arthroplasty.
نویسندگان
چکیده
Rotation errors of the femoral component are held responsible for occurrences such as instability in flexion and midflexion, patellar maltracking, and arthrofibrosis following total knee arthroplasty. However, in many cases, the epicondylar axis cannot be reliably identified due to bone defects or metal artifacts on computed tomography, so alternative landmarks are necessary to evaluate the femoral component rotation. The current study sought to determine the relationship of the posterior cortical bone and the anterior cortical bone in relation to the epicondylar axis. In this retrospective study, 398 consecutive patients who had undergone magnetic resonance imaging of the knee joint were included. The average angle between the posterior cortical bone and the epicondylar axis was 7.3°±3.3°. When the posterior cortical bone was used as the reference, the average absolute error was 2.6°±2.1°. In comparison, the average angle between the anterior cortical bone and epicondylar axis was 10.4°±4.5°. When this reference was used, the average absolute error was 3.6°±2.8°. The posterior cortical bone is a more consistent landmark than the anterior cortical bone is for intra- or postoperative approximation of the epicondylar axis. This appears to be due to the flat geometry of the posterior cortical bone compared with the elliptical form of the anterior cortical bone of the distal femur. In practice, an external rotation of the femoral component of 7° in relation to the posterior cortical bone is to be recommended. [Orthopedics. 2017; 40(3):188-190.].
منابع مشابه
Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)
Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملComputed Tomography Analysis of Postsurgery Femoral Component Rotation Based on a Force Sensing Device Method versus Hypothetical Rotational Alignment Based on Anatomical Landmark Methods: A Pilot Study
Rotation of the femoral component is an important aspect of knee arthroplasty, due to its effects on postsurgery knee kinematics and associated functional outcomes. It is still debated which method for establishing rotational alignment is preferable in orthopedic surgery. We compared force sensing based femoral component rotation with traditional anatomic landmark methods to investigate which m...
متن کاملRotational Alignment of the Femoral Component in Computer-Assisted Total Knee Arthroplasty
This study compared two Computer Assisted Surgery (CAS) methods in 212 total knee arthroplasties to evaluate the differences between anatomic landmark axes in determining rotational position of the femoral component. Overall, there were large variations between CAS defined component orientation using an optimized gap-balancing technique and component orientation using anatomic reference axes (r...
متن کاملBiomechanical Consequences of Anterior Femoral Notching in Cruciate-Retaining Versus Posterior-Stabilized Total Knee Arthroplasty.
Anterior femoral notching during total knee arthroplasty is a potential risk factor for periprosthetic supracondylar femur fracture. We conducted a study to determine if the design of the femoral implant changes the risk for periprosthetic supracondylar femur fractures after anterior cortical notching. An anterior cortical defect was created in 12 femoral polyurethane models. Six femora were in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 40 3 شماره
صفحات -
تاریخ انتشار 2017