Validation of Exposure Visualization and Audible Distance Emission for Navigated Temporal Bone Drilling in Phantoms
نویسندگان
چکیده
BACKGROUND A neuronavigation interface with extended function as compared with current systems was developed to aid during temporal bone surgery. The interface, named EVADE, updates the prior anatomical image and visualizes the bone drilling process virtually in real-time without need for intra-operative imaging. Furthermore, EVADE continuously calculates the distance from the drill tip to segmented temporal bone critical structures (e.g. the sigmoid sinus and facial nerve) and produces audiovisual warnings if the surgeon drills in too close vicinity. The aim of this study was to evaluate the accuracy and surgical utility of EVADE in physical phantoms. METHODOLOGY/PRINCIPAL FINDINGS We performed 228 measurements assessing the position accuracy of tracking a navigated drill in the operating theatre. A mean target registration error of 1.33±0.61 mm with a maximum error of 3.04 mm was found. Five neurosurgeons each drilled two temporal bone phantoms, once using EVADE, and once using a standard neuronavigation interface. While using standard neuronavigation the surgeons damaged three modeled temporal bone critical structures. No structure was hit by surgeons utilizing EVADE. Surgeons felt better orientated and thought they had improved tumor exposure with EVADE. Furthermore, we compared the distances between surface meshes of the virtual drill cavities created by EVADE to actual drill cavities: average maximum errors of 2.54±0.49 mm and -2.70±0.48 mm were found. CONCLUSIONS/SIGNIFICANCE These results demonstrate that EVADE gives accurate feedback which reduces risks of harming modeled critical structures compared to a standard neuronavigation interface during temporal bone phantom drilling.
منابع مشابه
Electron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel
Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...
متن کاملExperimental Visualization of Labyrinthine Structure with Optical Coherence Tomography
Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...
متن کاملVolume Computed Tomography for navigated procedures at the lateral skull base – proof of feasibility on phantom and human temporal bone specimens
Hypothesis: High-resolution imaging as provided by flat-panel based Volume Computed Tomography (fpVCT) could increase navigation accuracy and could therefore be valuable on lateral skull base procedures. O. Majdani S. Bartling Th. Rodt Methods: In the first part of the study we evaluated the accuracy of the image guided surgery (IGS) system using a custommade phantom that H. Eilers was scanned ...
متن کاملMetastatic Adenocarcinoma of Temporal Bone with Collet-Sicard Syndrome
Introduction: Metastatic tumors of the temporal bone are extremely rare. Collet-Sicard syndrome is an uncommon condition characterized by unilateral palsy of the lower four cranial nerves. The clinical features of temporal bone metastasis are nonspecific and mimic infections such as chronic otitis media and mastoiditis. Case Report: This report describes a rare case of metastatic adenocarcino...
متن کاملDrilling of the marginal tubercle to enhance exposure via mini pterional approach: An anatomical study and clinical series of 25 sphenoid wing meningiomas
BACKGROUND The marginal tubercle (MT) of zygomatic bone can be an obstacle in the standard mini pterional (MPT) craniotomy; we aim to evaluate the effect of drilling this MT in enhancing the exposure of MPT craniotomy for resection of sphenoid wing meningiomas (SWMs). METHODS The authors utilized 60 dry skulls to perform the anatomical part of the study. The MT size was reflected by the AB di...
متن کامل