Pharmacologic stress perfusion imaging with adenosine: role of simultaneous low-level treadmill exercise.
نویسندگان
چکیده
BACKGROUND Adenosine is commonly used for pharmacologic stress myocardial perfusion imaging (MPI). However, it frequently results in adverse effects, and the subdiaphragmatic tracer uptake may interfere with the image interpretation. Our aim was to determine the feasibility of combining low-level treadmill exercise with adenosine MPI and its impact on adverse effects, image quality, and myocardial ischemia. METHODS AND RESULTS Forty-one patients underwent technetium 99m sestamibi single photon emission computed tomography following adenosine and adenosine with low-level exercise (adenosine-Ex) on separate occasions and rest MPI. A comparison was made of symptoms, hemodynamic response, electrocardiographic changes, image quality, and image interpretation between the 2 protocols. With adenosine-Ex, fewer patients had one or more adverse effects (61% vs 90%; P =.006), more patients had ischemic electrocardiographic changes (34% vs 15%; P =.03), a higher percentage had excellent- or fair-quality images (88% vs 61%; P =.003), and they had higher heart-liver ratios (1.0 +/- 0.37 vs 0.84 +/- 0.29; P =.002) compared with adenosine alone. Four adenosine MPI studies, but only 2 adenosine-Ex studies, were uninterpretable because of excessive subdiaphragmatic radiotracer activity. Of the 39 patients with at least 1 interpretable stress study, interpretation was discordant in 11 (28%): 7 showed greater ischemia with adenosine-Ex, 2 uninterpretable adenosine studies were interpretable with adenosine-Ex, and 2 studies interpreted as abnormal with adenosine were normal by adenosine-Ex (both had normal coronary angiograms). CONCLUSIONS Simultaneous low-level treadmill exercise with adenosine Tc-99m sestamibi imaging is safe and feasible, significantly reduces unfavorable side effects, enhances image quality, and may result in greater ischemia detection compared with adenosine alone.
منابع مشابه
Benefits of combined pharmacologic and submaximal exercise stress on Sub-diaphragmatic activity in myocardial perfusion scintigraphy
Introduction: Myocardial perfusion imaging (MPI) is an important imaging modality in managing patients with cardiovascular disease. MPI has a significant role in diagnosis and management of cardiovascular disease; however it is subjected to different artifacts. Combining pharmacologic stress with submaximal exercise reduces side effects, improves image quality, and enhances the...
متن کامل[Adenosine stress protocols for myocardial perfusion imaging].
BACKGROUND/AIM Treadmill test combined with myocardial perfusion scintigraphy (MPS) is a commonly used technique in the assessment of coronary artery disease. There are many patients, however, who may not be able to undergo treadmill test. Such patients would benefit from pharmacological stress procedures combined with MPS. The most commonly used pharmacological agents for cardiac stress are co...
متن کاملComparison of treadmill exercise versus dipyridamole stress with myocardial perfusion imaging using rubidium-82 positron emission tomography.
OBJECTIVES This study assessed the feasibility of treadmill exercise rubidium-82 ((82)Rb) positron emission tomography (PET) and compared image quality and diagnostic content with dipyridamole (82)Rb PET in patients referred for evaluation of coronary artery disease (CAD). BACKGROUND Dipyridamole stress (82)Rb PET myocardial perfusion imaging (MPI) is an accurate imaging modality used to diag...
متن کاملThe feasibility of combining low-level exercise with vasodilator stress in patients referred for stress perfusion cardiac MRI
Background Adenosine, an agonist of the A2a receptor, is widely used for stress CMR. However, target receptors for adenosine are heterogeneous in their location and facilitated physiologic effects. A2b and A3 receptors are responsible for bronchospasm and peripheral arteriolar vasodilation; A1 receptors are responsible for AV block. The rate of adverse reactions with adenosine approaches 80%, c...
متن کاملDiagnostic Performance of Treadmill Exercise Cardiac Magnetic Resonance: The Prospective, Multicenter Exercise CMR's Accuracy for Cardiovascular Stress Testing (EXACT) Trial
BACKGROUND Stress cardiac magnetic resonance (CMR) has typically involved pharmacologic agents. Treadmill CMR has shown utility in single-center studies but has not undergone multicenter evaluation. METHODS AND RESULTS Patients referred for treadmill stress nuclear imaging (SPECT) were prospectively enrolled across 4 centers. After rest (99m)Tc SPECT, patients underwent resting cine CMR. In-r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2002