SU-E-T-494: Variation of Mucosal Dose in Head-And-Neck Radiotherapy: A Phantom Study Using Monte Carlo Simulation.

نویسندگان

  • J Chow
  • A Owrangi
چکیده

PURPOSE This phantom study investigated variations of mucosal dose on photon beam energy, beam angle, multi-beam configuration and mucosal thickness, when using small photon fields in head-and-neck radiotherapy. METHODS Cylindrical mucosa phantoms with bone and air heterogeneities were created with mucosal thickness (normal tissue) equal to 1, 2 and 3 mm. For dosimetric comparison, corresponding homogeneous phantom with all heterogeneities replaced by normal tissue was also used. These phantoms were irradiated by photon beams with field size = 1 × 1 cm2 . Beam energies of 6 and 18 MV were used with beam angles varied to 0°, 90° and 180°. Moreover, multi-beam configurations of 2, 4 and 8 beams were used, and doses along the central-beam axis in the mucosal tissue were calculated using Monte Carlo simulations (EGSnrc code). RESULTS For beam angle equal to 0°, the mucosal surface doses decreased slightly with an increase of the mucosal thickness (1-3 mm), while the surface dose of the 6 MV photon beam was decreased more significantly than the 18 MV. For beam angle equal to 180°, variation of muscosal surface dose with its thickness was found insignificant. For different multi-beam configurations, it was found that the variation of mucosal dose on its thickness became insignificant when the number of photon beams around the mucosa was increased. In addition, the change of mucosal dose due to the bone and air heterogeneities depended on the photon beam energy, beam angle and muscosal thickness. CONCLUSIONS It is concluded that mucosal dose depends on variations of beam energy, beam angle, multi-beam configuration and mucosal thickness for small photon fields. The dosimetric information in this study should be considered in studying the mucosal complications in head-and-neck IMRT, so that an optimized treatment strategy to minimize mucosal complications can be developed. This study is supported by the Dean’s Fund Grant in the University of Toronto.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

Monte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study

Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...

متن کامل

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study

Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations.Objective: The present study has been undertaken to find out inter- and intra- lung density variations and its dosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part17  شماره 

صفحات  -

تاریخ انتشار 2012