1 Low noise cryogenic electronics : preamplifier configurations with feedback on the bolometer

نویسنده

  • V. Sushkov
چکیده

We developed preamplifier configurations used to readout resistive bolometers such as those based on Neutron Transmuted Doped Germanium thermometers (so called NTD Ge thermometers)[1] or NbSi thin film thermometers [2, 3]. We introduce the impedance regulating preamplifier configuration. This configuration, is compared to previously proposed readout configurations with feedback on the bolometer [11]. It is shown that the impedance regulating preamplifier allows to achieve Extreme Electrothermal Feedback without using transition edge thermometer and SQUIDs readout. Thus the detector and readout electronics are straighforwardly calibrated and can handle much larger event rate. Furthermore, looped configurations simplify the design and improve performance of detection such as bandwidth. Finally, we show that the effects on signal to noise ratio are marginal. Over the last ten years, low temperature detectors have undergone extensive development. They address detection problems which require high sensitivity, high energy resolution and/or low thresholds: X-ray and far infrared spectroscopy, double beta decay, Dark Matter searches. Their performance critically depends on the quality of the thermometer used, and of the readout electronics and wiring of the apparatus. This paper describes some of the electronics we have developped for the EDELWEISS and Planck Surveyor collaborations. We assume in the following that the thermometers used are resistive, of the order of 1 MΩ resistance, or more. The temperature increase of the bolometer induces a variation of the thermometer impedance. In this context, JFETs are used as front end electronics to achieve low noise performance. We introduce a new preamplifier configuration: the impedance regulating preamplifier and discuss the properties of previously proposed preamplifier configurations with feedback on the bolometer[11] and of the classical unlooped voltage amplifier readout. Preamplifiers have been developed or are under test for each of these configurations. We will use a simple adiabatic model of bolometer with standard parametrisation to compute the bolometer's thermal behaviour. It is shown that feedback on bolometers yields significant changes in the detection behaviour such as natural calibration of the detector, shorter risetime, reduced relaxation time. Thus, it simplifies readout electronics, avoiding the complex additional circuits otherwise needed to achieve the same behaviour. The effect on signal to noise ratio are only marginal. We will summarise and compare the merits of the different readout configurations in the discussion. Detailed explanation of designs, performances and implementations of electronic boards will be published later. Thermal behaviour of a bolometer: the adiabatic approximation. 3 Figure 1) shows a simplified …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low noise cryogenic electronics : preamplifier configurations with feedback on the bolometer

We discuss the various electronic configurations one can use to readout resistive bolometers such as those based on Neutron Transmuted Doped Germanium thermometers (so called NTD Ge thermometers)[1] or NbSi thin film thermometers [2, 3]. The simple voltage amplifier configuration, is compared to readout configurations with feedback on the bolometer. Using the adiabatic thermal model of bolomete...

متن کامل

Very Low Noise Multiplexing with SQUIDs and SiGe Heterojunction Bipolar Transistors for Readout of Large Superconducting Bolometer Arrays

This paper presents an ultra low noise instrumentation based on a standard BiCMOS SiGe 0.35 μm ASIC operating at cryogenic temperatures. The main functions of the electronic circuit are the readout and the multiplexing of SQUIDs/TES. We report the cryogenic operation of the ASIC dedicated to the readout of a 2x4 pixel demonstrator array. We particularly emphasize on the development and the test...

متن کامل

Two Models for Bolometer and Microcalorimeter Detectors with Complex Thermal Architectures

We have developed two analytical models to describe the performance of cryogenic microcalorimeters and bolometers. One of the models is suitable to describe Transition Edge Sensor(TES) detectors with an integrated absorber, the other is suitable for detectors with large absorbers. Both models take into account hotelectron decoupling and absorber decoupling. The differential equations describing...

متن کامل

Leakage Current Compensation for the 0.13 μm CMOS Charge Sensitive Preamplifier

The active hybrid pixel detector (APD) can be a valuable solution in front-end electronics for radiation sensors. Detection systems with high sensor pixilation can benefit from low power, low parasitic, high front-end channel density, and low cost per channel. In addition, the APDs are characterized by good radiation tolerance [1-3] and can integrate large amount of additional signal processing...

متن کامل

Low-noise preamplifier with input and feedback transformers for low source resistance sensors

We describe the design, schematics, and performances of a very-low-noise, low-frequency preamplifier. It operates in the 5 Hz-100 kHz range and offers an input equivalent voltage noise density as low as 65 pV/ ,/I%; the current noise increases with frequency and settles to about 1.5 pA/ @ at 100 kHz. The amplifier uses input and feedback signal transformers and operates in full differential mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008