Semiautomated and automated algorithms for analysis of the carotid artery wall on computed tomography and sonography: a correlation study.
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to compare automated and semiautomated algorithms for analysis of carotid artery wall thickness and intima-media thickness on multidetector row computed tomographic (CT) angiography and sonography, respectively, and to study the correlation between them. METHODS Twenty consecutive patients underwent multidetector row CT angiographic and sonographic analysis of carotid arteries (mean age, 66 years; age range, 59-79 years). The intima-media thickness of the 40 carotid arteries was measured with novel and dedicated automated software analysis and by 4 observers who manually calculated the intima-media thickness. The carotid artery wall thickness was automatically estimated by using a specific algorithm and was also semiautomatically quantified. The correlation between groups was calculated by using the Pearson ρ statistic, and scatterplots were calculated. We evaluated intermethod agreement using Bland-Altman analysis. RESULTS By comparing automated carotid artery wall thickness, automated intima-media thickness, semiautomated carotid artery wall thickness, and semiautomated intima-media thickness analyses, a statistically significant association was found, with the highest values obtained for the association between semiautomated and automated intima-media thickness analyses(Pearson ρ = 0.9; 95% confidence interval, 0.82-0.95; P = 0.0001). The lowest values were obtained for the association between semiautomated intima-media thickness and automated carotid artery wall thickness analyses (Pearson ρ = 0.44; 95% confidence interval, 0.15-0.66; P = 0.0047). In the Bland-Altman analysis, the better results were obtained by comparing the semiautomated and automated algorithms for the study of intima-media thickness, with an interval of -16.1% to +43.6%. CONCLUSIONS The results of this preliminary study showed that carotid artery wall thickness and intima-media thickness can be studied with automated software, although the CT analysis needs to be further improved.
منابع مشابه
Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملCarotid artery thrombosis and cerebral infarction after multiple traumas
Carotid artery thrombosis and concomitant brain infarction after blunt trauma are rare conditions. We report a 34-year-old woman with multiple traumas due to pedestrian car accident. At the time of initial visiting, she was somnolent and her Glasgow coma scale (GCS) score was 14. Initial vital signs (V/S) and brain computed tomography (CT) scan were normal. One day after admission to the emerge...
متن کاملExtraction of the Longitudinal Movement of the Carotid Artery Wall using Consecutive Ultrasonic Images: a Block Matching Algorithm
Introduction: In this study, a computer analysis method based on a block matching algorithm is presented to extract the longitudinal movement of the carotid artery wall using consecutive ultrasonic images. A window (block) is selected as the reference block in the first frame and the most similar block to the reference one is found in the subsequent frames. Material and Methods: The program was...
متن کاملAlveolar Antral Artery: Does its Diameter Correlate with Maxillary lateral wall Thickness in Dentate Patients?
Introduction: Knowledge of the presence of the alveolar antral artery in the lateral maxillary sinus wall is essential for surgeons who operate in this region. The purpose of this study was to investigate the correlation between alveolar antral artery diameter and lateral maxillary bony wall thickness in dentate patients. Materials and Methods: Thirty five Cone-Beam Computed Tomography (CBCT)...
متن کاملCandida patients in a Jorjani center in Shahid Mohammadi Hospital of carotid Doppler sonnograghy findings in coronary artery Bypas grafting Bandar Abbas
Introduction: Nowadays caotid Dopplers sonography is gold standard for carotid artery screening in coronary aetery bypass grafting (CABG) candidates. This study was carried out in an angioplasty center in southern seaport in Iran to assesss theprevalence of artery stenosis and correlation of the atherosclerosis risk factor with the rate of artery stensis, and nence to define the high risk group...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 32 4 شماره
صفحات -