Surgeon Custom-Made Iliac Branch Device to Salvage Hypogastric Artery during Endovascular Aneurysm Repair
نویسندگان
چکیده
Endovascular salvage of the hypogastric artery using iliac branch device (IBD) during endovascular aortic aneurysm repair (EVAR), offers less invasive alternative solution to surgery to prevent pelvic ischemia. We have performed the first Korean surgeon custom-made IBD for this purpose to overcome the limitation of unavailability of the devices in Korea. Four patients with abdominal aortic aneurysm with bilateral common iliac artery aneurysm (CIAA) were treated using custom-made IBDs from October 2013 to December 2013. IBD was created in back table before EVAR operation using TFLE Zenith iliac limb stent graft (Cook Inc.). Three V12 (Atrium, Inc.) one Viabahn (Gore, Inc.) were used for bridging between IBD and target hypogastric artery. With this modification of IBD procedure, exteriorize the guide wire without snare device is possible which offers another benefit in terms of reducing medical costs comparing to commercial IBD. All operations were successful without any device related complications or postoperative endoleaks. During the mean follow up of 3 months, all IBD were patent without clinical complications. Surgeon custom made IBD is feasible and useful to preserve pelvic perfusion especially in the situation of limited commercial IBD availability in many countries. Long-term follow-up is needed to evaluate stent graft patency and IBD-related complications.
منابع مشابه
Successful off-label use of the GORE EXCLUDER Iliac Branch Endoprosthesis to preserve gluteal perfusion during staged endovascular repair of bilateral isolated hypogastric aneurysms
Endovascular repair of iliac artery aneurysms has emerged as an alternative to traditional open surgical repair. Although there is little consensus on indications to preserve hypogastric blood flow during aneurysm repair, it is well understood that complications from bilateral hypogastric occlusion may be significant. The GORE EXCLUDER Iliac Branch Endoprosthesis (W. L. Gore and Associates, Fla...
متن کاملUsing a Surgeon-modified Iliac Branch Device to Preserve the Internal Iliac Artery during Endovascular Aneurysm Repair: Single-center Experiences and Early Results
BACKGROUND To evaluate the feasibility of a new surgeon-modified iliac branch device (IBD) technique to maintain pelvic perfusion in the management of common iliac artery (CIA) aneurysm during endovascular aneurysm repair (EVAR). METHODS From January 2011 to December 2013, a new surgeon-modified IBD technique was performed in department of vascular surgery of Peking Union Medical College Hosp...
متن کاملInferior Mesenteric Artery Side Branch for Selected Patients with Endovascular Aortic Aneurysm Repair
OBJECTIVE/BACKGROUND To report on our experience of the treatment of aortic aneurysms by custom-made, branched stent-grafts with an additional inferior mesenteric artery (IMA) side branch to preserve IMA perfusion in patients at risk for colon ischemia. METHODS Three male patients (mean age 60 years) with a thoracoabdominal, pararenal, and infrarenal aortic aneurysm (AA), respectively, were t...
متن کاملSuccessful endovascular coiling of a ruptured internal iliac artery aneurysm: a case report
Ruptured internal iliac artery aneurysms (IIAA) are extremely rare, and the repair can be challenging. This case reports described an 83-year-old patient who presented at our Emergency Department with acute abdominal pain based on a ruptured IIAA. He refused open repair and only wanted to be treated as minimally invasive as possible. Therefore endovascular embolization of the IIAA was performed...
متن کاملRupture of Hypogastric Artery Aneurysm Following Failed Endovascular Repair: A Case Report
Hypogastric artery aneurysms are usually associated with aortic and common iliac aneurysm and rarely occur in isolation [1-6]. The majority of hypogastric artery aneurysms are incidentally detected on imaging of the abdomen or pelvis for unrelated complaints. Those that present in extremis are associated with acute rupture and carry a high mortality rate [1,2]. Herein we present a case of an in...