Doses to patients from photoneutrons emitted in a medical linear accelerator.
نویسندگان
چکیده
This study of doses to patients from emitted photoneutrons in a medical linear accelerator (Varian 2100C) was carried out. Dose calculation was performed using Monte Carlo Geant4 code. The model was used to calculate the neutron fluence, as a function of the neutron energy inside the treatment room to estimate the effective dose to patients. The ambient dose equivalent versus field size for patients is reported in this study. The ambient dose equivalent using 1 x 1 cm(2) field size, at isocentre and X-ray modes of 20, 18, 15 and 10 MV, was found to be 1.85, 1.79, 0.61 and 0.06 mSv Gy(-1), respectively. The mean energies of emitted photoneutrons were 0.48, 0.44, 0.40 and 0.16 MeV at X-ray modes of 20, 18, 15 and 10 MV, respectively. The results of ambient dose equivalent from emitted photoneutrons cannot be ignored and can represent a risk for healthy tissues. This study emphasised that Geant4 Monte Carlo code is an appropriate choice for studying photoneutron production and transport.
منابع مشابه
A Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator
Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...
متن کاملA Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator
Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...
متن کاملThe Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study
BackgroundOne of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is used to delivering doses. Compensator-based IMRT treatment is usually operated with an energy higher than 10 MV. Photoneutrons, which have high linear energy transfer and radiobiol...
متن کاملPhotoneutrons from medical linear accelerators--radiobiological measurements and risk estimates.
PURPOSE To assess the oncogenic potential of the photoneutrons produced by high energy medical linear accelerators. METHODS AND MATERIALS An established line of cells of rodent origin (C3H 10T1/2) was used to assess the oncogenic potential of the radiation dose received in the breast of an anthropomorphic "randoman" phanton, while the cervix received a dose of 70 Gy. Experiments were performe...
متن کاملA Monte Carlo Study for Photoneutron Dose Estimations around the High-Energy Linacs
Background: High-energy linear accelerator (linac) is a valuable tool and the most commonly device for external beam radiation treatments in cancer patients. In the linac head, high-energy photons with energies above the threshold of interaction produce photoneutrons. These photoneutrons deliver the extra dose to the patients in the planning treatment and increase the risk of secondary cancer.O...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 133 3 شماره
صفحات -
تاریخ انتشار 2009