Voltammetry on BICUVOX . 10 microsamples
نویسنده
چکیده
BICUVOX.10 (Bi Cu V O ) might be a very attractive material for use in oxygen sensors, fuel cells and oxygen 2 0.1 0.9 5.35 separators. The electrochemical stability of BICUVOX.10 is an important factor for its future application. The electrochemical reduction and oxidation can be recognized very easily by the voltammetric technique. Our previous voltammetric measurements were made on 3-electrode cells like Pt,O uBICUVOX.10uO ,Pt using BICUVOX.10u0 ,Pt as reference 2 2 2 electrode. This investigation showed a reduction of the material in the cathodic scan, followed by an oxidation peak in the anodic one. However, a quantitative elucidation of the reduction processes was not possible. The use of small samples in a cell of the arrangement Pt,ArusampleuYSZuAr,Pt allows to distinguish between different reduction steps during the negative sweep. The reference electrode was a platinum point electrode applied to YSZ. Because of the small size of a sample it can be reduced to a large extent at temperatures above 6008C. We found that the sample started to be reduced irreversibly below 2 570 mV against the reversible oxygen electrode in 1 atm O during the first negative sweep. Only part of the reduced 2 sample can be reoxidised during the next positive sweep. The subsequent cycles showed reversible reduction and oxidation of the residual oxides. 1998 Published by Elsevier Science B.V. All rights reserved.
منابع مشابه
Voltammetric measurements on Me O ( Me 5 Bi , Cu , V ) x y compounds and comparison with results for BICUVOX . 10
Voltammetric measurements on cells of arrangement Pt,ArusampleuYSZuAr,Pt with a very small sample mass (‘microsamples’) turned out to be a very convenient tool for the determination of thermodynamic properties of oxides. Measurements were made on Bi O , CuO and V O microsamples and on nickel and copper metal between 550 and 7008C. The 2 3 2 5 measurements on nickel were used for the calibration...
متن کاملVoltammetry on BIMEVOX . 10 ( ME 5 Cu , Ni , Zn , Mg ) microsamples
High temperature cyclic voltammetry on microsamples was used for the investigation of the electrochemical stability of BIMEVOX.10 materials. The electrochemical measurements were performed on a three-electrode cell of the type: PtumicrosampleuYSZuPt with the interface PtuYSZ as a pseudo reference electrode. The experiments were performed in nitrogen containing a small quantity of oxygen. The ce...
متن کاملAutomated device for electrochemical measurements and application to the system Pt / solid electrolyte
An automated device for voltammetric measurements at a prescribed set of constant temperatures was put together in our institute. It allows one to take steady-state current-potential curves in the potentiostatic or galvanostatic mode, to do cyclic voltammetry or coulometry at constant potential or to measure the potential-time dependence at a constant current. A special holder for the solid ele...
متن کاملMicroscale diversity of the genus Nitrobacter in soil on the basis of analysis of genes encoding rRNA.
We looked at the diversity of [NO(2)](-) oxidizers at field scale by examining isolates at clump scale and in microsamples of soil (diameter, 50 microm). The genetic distances (as determined by amplified ribosomal DNA restriction analysis performed with Nitrobacter-specific primers) in a small clump of soil were as large as those between reference strains from large geographical areas. Diversit...
متن کاملComparative two - and four - probe impedance measurements on BICUVOX
In two-probe impedance measurements the interfacial impedance between metal electrode and ionic conductor contributes to the measured impedance. Therefore a calculation procedure which separates the bulk from the interfacial impedance must be applied. The separation procedure can be avoided by measuring the bulk conductivity in the four-probe arrangement. The impedance of polycrystalline sample...