A high-throughput structural biology/proteomics beamline at the SRS on a new multipole wiggler.

نویسندگان

  • Michele Cianci
  • Svetlana Antonyuk
  • Neil Bliss
  • Mike W Bailey
  • Stephen G Buffey
  • Kan C Cheung
  • Jim A Clarke
  • Gareth E Derbyshire
  • Mark J Ellis
  • Mark J Enderby
  • Alan F Grant
  • Martin P Holbourn
  • David Laundy
  • Colin Nave
  • Roy Ryder
  • Paul Stephenson
  • John R Helliwell
  • S Samar Hasnain
چکیده

The North West Structural Genomics Centre's beamline, MAD10, at the SRS receives the central part of the radiation fan (0.5 mrad vertically, 4 mrad horizontally) produced by a new 2.46 T ten-pole wiggler. The optical arrangement of the beamline consists of a Rh-coated collimating Si mirror, a fixed-exit-beam double-crystal monochromator with sagittal bending for horizontal focusing and a second Rh-coated Si mirror for vertical focusing. The double-crystal Si (111) monochromator allows data collection in the 5-13.5 keV photon energy range with rapid (subsecond) tunability and high energy resolution. The monochromatic beam is optimized through a 200 microm collimator. The beamline end station has been designed around a Mar desktop beamline with high-throughput cryogenic sample changer, Mar225 CCD detector, liquid-N(2) autofill system and an ORTEC C-TRAIN-04 energy-resolving high-count-rate X-ray fluorescence detector. The instrument is optimized for MAD/SAD applications in protein crystallography with the additional mode of operation of online single-crystal EXAFS studies on the same crystals. Thus, screening of metals/Se in the crystal can be performed quickly prior to MAD/SAD data collection by exciting the crystal with X-rays of appropriate energy and recording an energy-dispersive fluorescence spectrum. In addition, this experimental set-up allows for parallel XAFS measurements on the same crystal to monitor 'radiation-induced' changes, if any, in e.g. the redox state of metal centres to be detected for a 'metallic' functional group during crystallographic data collection. Moreover, careful minimization of the thickness of the Be window maximizes the intensity performance for the 2.0-2.5 A softer wavelength range. This range also covers the K-edges of a number of important 3d transition metals as well as the L-edges of xenon and iodine and enhanced sulfur f ''.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The new HMI beamline MAGS: an instrument for hard X-ray diffraction at BESSY.

The Hahn-Meitner-Institute Berlin is operating the new hard X-ray diffraction beamline MAGS at the Berlin synchrotron radiation source BESSY. The beamline is intended to complement the existing neutron instrumentation at the Berlin Neutron Scattering Centre. The new beamline uses a 7 T multipole wiggler to produce photon fluxes in the 10(11)-10(12) photons s(-1) (100 mA)(-1) (0.1% bandwidth)(-1...

متن کامل

The Design, Construction and Testing of a Multipole Wiggler Magnet Titanium Vacuum Chamber for the Srs

A vacuum chamber is required for two new insertion devices (IDs) at the SRS. The chamber has been designed, finite element analysis performed, and a prototype constructed and successfully tested. The chamber is 1208 mm in length, it has an internal aperture of 134 mm x 16 mm and a minimum wall thickness of 1 mm. The chamber has been precision machined in two halves from titanium alloy and elect...

متن کامل

VUV irradiation effects on proteins in high-flux synchrotron radiation circular dichroism spectroscopy.

Synchrotron radiation circular dichroism (SRCD) spectroscopy is emerging as an important new tool in structural molecular biology. Previously we had shown that in lower-flux SRCD instruments, such as UV1 at ISA and beamline 3.1 at the SRS, vacuum ultraviolet (VUV) radiation damage to proteins was not evident after exposure over a period of hours. No effects were detected in either the protein p...

متن کامل

The macromolecular crystallography beamline I911-3 at the MAX IV laboratory

The macromolecular crystallography beamline I911-3, part of the Cassiopeia/I911 suite of beamlines, is based on a superconducting wiggler at the MAX II ring of the MAX IV Laboratory in Lund, Sweden. The beamline is energy-tunable within a range between 6 and 18 keV. I911-3 opened for users in 2005. In 2010-2011 the experimental station was completely rebuilt and refurbished such that it has bec...

متن کامل

Bent-crystal monochromators for high-energy synchrotron radiation.

Two kinds of monochromators covering the energy ranges 100-150 keV and approximately 300 keV have been designed for inelastic (Compton) scattering experiments at the elliptical multipole wiggler beamline, BL08W, of SPring-8. Finite-element analyses using ANSYS for bent crystals indicate that thermal problems are not serious for the 300 keV monochromator, while an energy spread of about 10(-3) f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 12 Pt 4  شماره 

صفحات  -

تاریخ انتشار 2005