INTRODUCTION This study investigates how a particular incorrect electrode configuration affects the 12-lead Electrocardiogram (ECG). METHODS A correct and an incorrect 12-lead ECG were extracted from a 192-lead BSPM. This was done for 232 BSPMs yielding 464 12-lead ECGs. The particular incorrect ECG involved displacing electrodes V1 and V2 in the second intercostal space whilst also offsetting the remaining electrodes. These ECGs were examined in two stages: (a) analysis of the effects of electrode misplacement on signal morphology and (b) analysis of how often the incorrect electrode configuration changed the diagnosis of two clinicians in a random sample of 75 patients. RESULTS According to the Root Mean Square Error (RMSE) of the difference between PQRST intervals in the correct and incorrect ECGs, lead V2 is the most affected lead (mean: 185 μV ± 82 μV), followed by lead V4 (mean: 114 μV ± 59 μV) and lead V1 (mean: 100 μV ± 47 μV). It was found that if the incorrect electrode configuration is applied, there is a 17% to a 24% chance the diagnostic interpretation will be different. Quantified using Similarity Coefficient (SC) leads V1 and V2 were found to be more alike when misplaced in the second intercostal space. The average SC between these leads when correctly placed was 0.08 (± 0.65), however when incorrectly placed, the average SC was 0.43 (± 0.3). CONCLUSION There is a reasonable chance this particular incorrect electrode configuration will change the diagnosis of the 12-lead ECG. This highlights the importance of developing algorithms to detect electrode misplacement along with better education regarding ECG acquisition.
منابع مشابه
Methods of Teaching Electrocardiogram: Which One Is the Best?
Introduction: There are many methods for teaching ECG interpretation, but deciding on the best method is yet to be discussed. The purpose of this research was to examine teaching methods for ECG interpretation and introduce the most effective ones. Methods: This systematic review was conducted by searching through scientific databases of PUBMED, Science Direct, SID and IranMedex. Papers publish...
متن کاملEffects of tramadol on electrocardiogram, mean electrical axis and respiration in Kagani goats (Capra hircus)
The effects of tramadol on electrocardiogram (ECG), mean electrical axis and respiratory rates were studied in adult kagani goats after intramuscular administration of tramadol at 1 mg/kg b.wt. as a prelude to its clinical use as an analgesic in veterinary practice. The ECG was monitored by standard bipolar leads and discernible electrocardiographic features were observed in lead II. The normal...
متن کاملImmediate Lead Positioning Feedback for ML based wearable ECG
Wearable ECG devices are used in combination with smartphones to capture, analyze and transmit ECG data to far away hospitals where doctors analyze, diagnose and provide necessary patient feedback. ECG electrode cable misplacement is a significant challenge when untrained patients use them, especially among rural population. Lead misplacement algorithms exists for standard ECG electrode positio...
متن کاملEvaluation of Electrocardiogram Changes in Patients with Slow Coronary Flow
Background: Slow coronary flow (SCF) is defined as a condition in which in spite of no evidence of coronary occlusion or stenosis in angiography, there is delayed pacification of the vessels after the injection of a contrast agent. There are several studies about electrocardiogram (ECG) changes in these patients, but changes like OLD MI, RBBB, LBBB, LVH and ST-T wave have not b...
متن کاملModified electrode placement must be recorded when performing 12-lead electrocardiograms.
BACKGROUND Local observation has suggested that placing limb leads on the torso when recording the standard 12-lead resting electrocardiogram (ECG) has become commonplace. This non-standard modification has the important advantages of ease and speed of application, and in an emergency may be applied with minimal undressing. Limb movement artefact is also reduced. It is believed that ECGs obtain...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of internal medicine
دوره 23 7 شماره
صفحات -
تاریخ انتشار 2012