Influence of Corneal Opacity on Intraocular Pressure Assessment in Patients with Lysosomal Storage Diseases

نویسندگان

  • Joanna Wasielica-Poslednik
  • Giuseppe Politino
  • Irene Schmidtmann
  • Katrin Lorenz
  • Katharina Bell
  • Norbert Pfeiffer
  • Susanne Pitz
چکیده

AIMS To investigate an influence of mucopolysaccharidosis (MPS)- and Morbus Fabry-associated corneal opacities on intraocular pressure (IOP) measurements and to evaluate the concordance of the different tonometry methods. METHODS 25 MPS patients with or without corneal clouding, 25 Fabry patients with cornea verticillata ≥ grade 2 and 25 healthy age matched controls were prospectively included into this study. Outcome measures: Goldmann applanation tonometry (GAT); palpatory assessment of IOP; Goldmann-correlated intraocular pressure (IOPg), corneal-compensated intraocular pressure (IOPcc), corneal resistance factor (CRF) and corneal hysteresis (CH) assessed by Ocular Response Analyzer (ORA); central corneal thickness (CCT) and density assessed with Pentacam. Statistical analysis was performed using linear mixed effect models and Spearman correlation coefficients. The concordance between tonometry methods was assessed using Bland-Altman analysis. RESULTS There was no relevant difference between study groups regarding median GAT, IOPg, IOPcc and CCT measurements. The limits of agreement between GAT and IOPcc/IOPg/palpatory IOP in MPS were: [-11.7 to 12.1mmHg], [-8.6 to 15.5 mmHg] and [- 5.4 to 10.1 mmHg] respectively. Limits of agreement were less wide in healthy subjects and Fabry patients. Palpatory IOP was higher in MPS than in healthy controls and Fabry patients. Corneal opacity correlated more strongly with GAT, IOPg, CH, CRF, CCT and corneal density in MPS (r = 0.4, 0.5, 0.5, 0.7, 0.6, 0.6 respectively) than in Fabry patients (r = 0.3, 0.2, -0.03, 0.1, 0.3, -0.2 respectively). In contrast, IOPcc revealed less correlation with corneal opacity than GAT in MPS (r = 0.2 vs. 0.4). CONCLUSIONS ORA and GAT render less comparable IOP-values in patients suffering from MPS-associated corneal opacity in comparison to Fabry and healthy controls. The IOP seems to be overestimated in opaque MPS-affected corneas. GAT, IOPg and biomechanical parameters of the cornea correlate more strongly with the corneal clouding than IOPcc in MPS patients. TRIAL REGISTRATION ClinicalTrials.gov NCT01695161.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

بررسی تأثیر اعمال جراحی پیوند ثانویه عدسی داخل چشمی

Background and purpose : Many aphahic patients have unfavorable vision either with glasses or contact lens. In this study Visual outcome of Seconary (I.O.L) was implantation in aphakic patients referred to Imam Hossein Haspital 1994 evaluated. Materials and Methods : In a clinical trial with sequential sampling , 30 aphakic patients (26 males , 4 females mean of age 24.4 ± 10.8 years) who...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy

Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...

متن کامل

Effect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)

Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017