Measurement of total bilirubin by use of bilirubin oxidase.
نویسندگان
چکیده
We used an enzymatic method for measuring total bilirubin in serum. Results by this method varied linearly with bilirubin concentrations to at least 300 mg/L. The day-to-day precision (CV) of the method ranged from less than 1% to about 11% at bilirubin concentrations of 183 and 12 mg/L, respectively. Commonly used anticoagulants, serum preparation materials, and selected drugs had no effect on the apparent bilirubin concentration, but turbidity caused a slight increase and hemoglobin concentrations of 2 g/L resulted in lower values, by as much as 17 mg/L at a bilirubin concentration of 95 mg/L. Patients' results obtained with this enzymatic method were slightly lower than those obtained with methods based on the Jendrassik-Grof principle. The largest differences, seen in samples with high "direct" bilirubin concentrations, can be decreased by measuring the absorbance at 425 nm instead of at 465 nm as recommended by the supplier of the bilirubin oxidase method.
منابع مشابه
The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran
The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...
متن کاملA Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates
Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...
متن کاملMeasurement of direct bilirubin by use of bilirubin oxidase.
We developed an enzymatic method for measuring direct-reacting bilirubin (DBIL) in serum. At pH 4.5, bilirubin oxidase (BOX) oxidizes mono-conjugated bilirubin, di-conjugated bilirubin, and most of the delta-bilirubin to biliverdin. The resulting decrease in absorbance at 460 nm is linearly related to the concentration of DBIL in serum. Mean DBIL values in the 51 patients' sera examined by the ...
متن کاملOperational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory
OBJECTIVES The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. DESIGN AND METHODS Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was ...
متن کاملElimination of the "chromogen oxidase" activity of bilirubin oxidase added to obviate bilirubin interference in hydrogen peroxide/peroxidase detecting systems.
The use of bilirubin oxidase to remove interference by bilirubin in hydrogen peroxide/peroxidase detecting systems is hampered by its inherent "chromogen oxidase" activity (its ability to oxidize the chromogens used in the systems). This unwanted activity is greater than 99% inhibited by 0.5 mmol/L cyanide, 97% inhibited by 20 mmol/L azide. At these same concentrations, they inhibit bilirubin o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1986