Continuum and discrete pulsed cavity ring down laser absorption spectra of Br2 vapor.
نویسندگان
چکیده
The absorption cross-sections at room temperature are reported for the first time, of Br2 vapor in overlapping bound-free and bound-bound transition of A(3)pi1u <-- Xsigma(g)+, X(1)pi1u <-- X(1)sigma(g)+ and B(3)pi0u <-- X(1)sigma(g)+, using cavity ring down spectroscopy (CRDS) technique. We reported here, the A(3)pi1u <-- X(1)sigma(g)+, transition is included along with the two stronger X(1)pi1u <-- X(1)sigma(g)+ and B(3)pi0u <-- X(1)sigma(g) transitions of Br2. We obtained discrete absorption cross-section in the rotational structure, the continuum absorption cross-sections, and were also able to measure the absorption cross-section in separate contribution of A(3)pi1u <-- X(1)sigma(g)+, (1)pi1u <-- X(1)sigma(g)+, and B(3)pi0u <-- X(1)sigma(g)+ transitions using CRDS method to use quantum yield of Br*((2)P(1/2)). We obtained absorption cross-section order 10(-19) cm2 and detection 10(13) molecule cm(-3) (1 mTorr) of Br2. The absorption cross-sections are increasing with increasing excitation energy in the wavelength region 510-535 nm.
منابع مشابه
Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
We have developed a technique which allows optical absorption measurements to be made using a pulsed light source and offers a sensitivity significantly greater than that attained using stabilized continuous light sources. The technique is based upon the measurement of the rate of absorption rather than the magnitude of absorption of a light pulse confined within a closed optical cavity. The de...
متن کاملCavity-Ring-Down Spectroscopy on Water Vapor in the Range 555-604 nm.
The method of pulsed cavity-ring-down spectroscopy was employed to record the water vapor absorption spectrum in the wavelength range 555-604 nm. The spectrum consists of 1830 lines, calibrated against the iodine standard with an accuracy of 0.01 cm(-1); 800 of these lines are not obtained in the HITRAN 96 database, while 243 are not included in the newly recorded Fourier transform spectrum of ...
متن کاملInfrared water vapor continuum absorption at atmospheric temperatures.
We have used a continuous-wave carbon dioxide laser in a single-mode realization of cavity ring-down spectroscopy to measure absorption coefficients of water vapor at 944 cm(-1) for several temperatures in the range 270-315 K. The conventional description of water vapor infrared absorption is applied, in which the absorption is modeled in two parts consisting of local line absorption and the re...
متن کاملEvanescent Wave Cavity Ring-down Spectroscopy: a Future Technology for Process Sensing
Evanescent wave cavity ring-down spectroscopy (EW-CRDS) is described. The total internal reflection (TIR)-ring and monolithic folded cavity designs are briefly discussed. The performance of EW-CRDS for trace water vapor detection is evaluated by accounting for surface chemical and physical properties as well as intrinsic resonator properties. INTRODUCTION Cavity ring-down spectroscopy (CRDS) us...
متن کاملPound-Drever-Hall-locked, frequency-stabilized cavity ring-down spectrometer.
We describe a high sensitivity and high spectral resolution laser absorption spectrometer based upon the frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) technique. We used the Pound-Drever-Hall (PDH) method to lock the probe laser to the high-finesse ring-down cavity. We show that the concomitant narrowing of the probe laser line width leads to dramatically increased ring-down even...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
دوره 61 9 شماره
صفحات -
تاریخ انتشار 2005